$ 11824.00Ex works
Temperature range -40~ 130 ℃, Temperature Uniformity +/- 2 ℃, using fluorine-free environmental protection refrigerant and imported Compressor, with multi-stage programming function and independent temperature limit alarm system, support data export and remote monitoring.
Category : High Low Temperature Test Chamber
Brand : YiHeng
SKU : NB038675
Service :The delivery and service By NBCLab.Com
YIHENG BPH-1000B low/high temperature test Chamber is a new generation of high and low temperature (alternating) test equipment, integrating the company's many years of box design experience, in line with the humanized design concept, starting from the actual needs of customers, meeting customer requirements in details, providing high-quality products. Imported Humidity controller and environmentally friendly design ensure easy operation and health and environmental protection.
1. Fluorine-free environmentally friendly design, in line with the concept of healthy living 2. Imported Temperature and Humidity Controller Long Life, High Accuracy CFL20 Word × 6 Line LCD Display, Easy Keyboard Input Operation 3. There is a 25mm or 50mm diameter test hole on the left side of the box, which is convenient for experimental operation and temperature measurement 4. Imported brand Compressor and circulating fan, uniform temperature distribution, high efficiency of environmentally friendly refrigerant and low energy consumption 5. Unique air duct circulation system to ensure uniform working room temperature Humidity 6. Imported 304 mirror stainless steel liner, excessive four corners and half arcs, free loading and unloading of shelf brackets, easy to clean 7. Multi-stage programmable control, simplifying the complex test process and realizing automatic control and operation 8. Independent temperature limit alarm system, automatic interruption of operation and sound and light alarm to ensure safety 9. High temperature, low temperature and over-temperature alarm, Compressor overheating, overcurrent, overload protection, fan overheating protection 10. Can be connected to printer or 485 Communication interface, USB data transfer interface, support computer display and printing Humidity Linear dispersion 11. Programmable Touchscreen Controller (Standard), Color LCD Touchscreen, Menu Operating interface, Chinese and English optional, Display real-time Temperature Humidity Linear dispersion 12. Can set 120 sets of 99 segments per group, 999 cycles, each segment can be set for 999 hours, 59 minutes and 59 seconds, with screen lock function 13. With P.I.D automatic calculation function, temperature and Humidity control is accurate and stable 14. With RS-232 or RS-485 Communication interface, computer design program, monitor the test process and perform switch 15. Professional Control Software supports monitoring and controlling 30 devices simultaneously, analyzing and storing data in real time, and forming Excel or Word documents
The low/high temperature test Chamber realizes temperature control through imported Compressors and refrigeration systems, and uses environmentally friendly refrigerants to improve efficiency and reduce energy consumption. The unique air duct circulation system ensures uniform distribution of Humidity at working room temperature. The programmable controller corrects the temperature and Humidity changes in real time through P.I.D automatic calculation to achieve precise and stable control. Multi-stage programming function simplifies the test process, supports automatic operation and data monitoring.
Electronic product testing, material research, automotive parts testing, aerospace testing, chemical product testing, pharmaceutical research and development, environment simulation testing
Fluorine-free environmental protection standards, Temperature and Humidity control standards, Safety protection standards
1. Connect the power supply AC380V 50Hz to ensure that the equipment is grounded 2. Turn on the device power and start the Humidity Controller 3. Set the Temperature and Humidity parameters through the keyboard or Touchscreen, and choose the multi-segment programming mode 4. Connect test holes for experimental operation and temperature measurement as required 5. Start operation, the equipment automatically controls temperature and Humidity changes 6. Monitor running status, view data and Linear dispersion in real time through computer software 7. After the experiment, turn off the power of the equipment for cleaning and maintenance
Equipment must be grounded to avoid electrical hazards • Temperature range does not exceed -40~ 130 ℃ to prevent overrun • Regularly check the status of the Compressor and fan to ensure normal operation • Avoid continuing to operate when over-temperature alarm, and deal with the fault in time • Use a soft cloth when cleaning the studio to avoid scratching the stainless steel liner • Pay attention to the number of cycles and time when programming settings to prevent misoperation • Communication interface to ensure stable connection to avoid data loss • Do not block the ventilating port when the equipment is running, keep good heat dissipation
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.