Overview
The LEICI PHB-5 Portable pH Meter is a High Accuracy measuring instrument with a high definition LCD display and push button operation, intelligent detection and data management capabilities for quick ph value measurement in the field.
Features
1. High definition LCD display, easy to operate buttons
2. Support boot self-diagnosis, automatic shutdown, power-off protection and factory reset
3. Support firmware upgrade, allowing function expansion and personalized customization
4. IP65 Protection Rating, Dustproof and Waterproof
5. Standard triple compound pH Electrode, Electrode hanger, silicone protective cover, wristband and calibrated buffer powder
6. Intelligent detection and automatic identification functions
7. Intelligent determination of endpoints, support equilibrated measurement and continuous Measurement mode
8. Support automatic/manual temperature compensation
9. Support pH Electrode 1-3 point calibration, automatic identification of standard buffer solution
10. Data storage, access and deletion (200 sets each)
11. Large-capacity lithium battery power supply, supports PC and mobile power charging
12. With battery undervoltage reminder and charging status reminder functions
13. Support backlight adjustment
Principle
The instrument detects the concentration of hydrogen ions in the solution by triple composite pH Electrode, converts the signal into pH value display; adopts intelligent end point determination technology, combined with temperature compensation and calibration functions to ensure measurement accuracy and Stability.
Applications
Water quality monitoring, environment testing, laboratory analysis, industrial process control, education and research
Standards
Instrument level 0.01, pH Measurement range -2.00~ 18.00pH, pH resolution 0.01pH, pH Electronic Unit Indication Error +/- 0.01pH, mV Measurement range -1999~ 1999mV, mV resolution 1mV, mV Electronic Unit Indication Error +/- 0.1% FS
Steps
1. Turn on the self-test to confirm the status of the instrument
2. Select equilibrate measurement or continuous Measurement mode as needed
Electrode calibration of pH (1-3 points) with automatic identification or custom buffer solution
4. Electrode is immersed in the solution to be tested, and the pH value is read after intelligently determining the end point
5. Data is automatically stored to support subsequent access and management
6. Clean Electrode after use, shut down or automatically shut down
Notice
• Electrode integrity before use to avoid violent collisions
• Standard buffer solution is used during calibration to ensure accuracy
• Pay attention to temperature compensation settings during measurement to avoid environment interference
• Charge regularly, pay attention to the battery undervoltage reminder
• Keep the instrument drying to meet IP65 protection requirements
• Follow the instructions when upgrading the firmware to prevent data loss