Adopt dual array CMOS image sensor with high Sensitivity and wide Light spectrum Response range. Repeatability Delta E * ab can be controlled within 0.01, Inter-instrument Agreement Delta E * ab can be controlled within 0.12, and the data is stable and reliable. Provides φ 1mm micropore diaMeter, suitable for small area samples.
Category : Colorimeter
Brand : 3NH
SKU : NB039086
Service :The delivery and service By NBCLab.Com
Benchtop Colorimeter TS8216 is a Colorimeter developed by 3nh using its own spectroscopic core technology. It adopts a dual-array CMOS image sensor with high Sensitivity and a wide Light spectrum Response range, resulting in more accurate testing. Its Repeatability Delta E * ab is easily controlled within 0.01, and the Inter-instrument Agreement Delta E * ab is controlled within 0.12. The data is stable and reliable, and can be used for accurate analysis and transmission of laboratory Color.
1. Micropore diameter: provide reflection: → 0.3mm/0.5mm/1mm (only one diameter is selected) Transmission: medium 8mm/4mm (only one diameter is selected), used for chroma control of small area reflection samples and small capacity transmission samples. 2. Adopt international common D/8 structure, compatible with SCI/SCE measurement, and support SCI + SCE simultaneous fast measurement. 3. Dual Array CMOS Image Sensor: High Sensitivity and Wide Light spectrum Response Range Ensure Instrument Measurement speed, Accuracy, Stability and conformity. 4, a variety of Color measurement space, a variety of observation Illuminant: provide a variety of Color space and observation Illuminant, can meet the special measurement needs under different measurement conditions. 5, the use of a combination of Full Light spectrum LED Illuminant, UV Illuminant: Full-band Balanced LED Illuminant to ensure that there is sufficient Light spectrum distribution in the visible range, to avoid the white LED in a specific band of Light spectrum loss, to ensure the instrument Measurement speed and accuracy of measurement results, professional UV Illuminant to ensure more reliable UV testing. 6. Measurement verification report: Each instrument has been verified and tested, and the measurement data Traceability is sent to the National Measurement Institute to ensure the credibility of the instrument test data. 7, industrial high definition Touchscreen, easy to use user interface: 7 inch industrial high definition Touchscreen, smooth control, simple and easy to use user interface makes the operation comfortable, convenient and easier to use. 8. Color management software: The SQCX quality management software is suitable for quality monitoring and Color data management in various industries. It digitizes the user's Color management, compares Color differences, generates test reports, provides a variety of color space measurement data, and customizes the customer's Color management work.
The TS8216 Benchtop Colorimeter uses concave grating spectroscopy technology, and the illumination mode is reflection: D/8 (diffuse illumination, 8 ° direction reception) SCI/SCE measurement; transmission: D/0 (diffuse illumination, 0 ° direction reception) SCI/SCE measurement. The instrument uses a 360~ 780nm combination LED Illuminant and a professional UV Illuminant to capture Light spectrum information through a 256-pixel dual-array CMOS image sensor, and analyzes it at 10nm intervals in the 360~ 780nm Wavelength range to achieve accurate Color measurement.
Color analysis and transfer laboratory, plastic electronics, paints inks, Spinning & weaving garment printing, printing, paper, cosmetics, food
CIE No.15、GB/T 3978、GB 2893、GB/T 18833、ISO7724/1、ASTM E1164、DIN5033 Teil7
1. The instrument is turned on to warm up. 2. Perform instrument calibration. 3. Measurement mode (reflection or transmission) and corresponding measurement aperture. 4. Select the desired Color Space and Observational Illuminant. 5. Place the sample to be tested. 6, start the measurement, the instrument about 2.4 seconds (while testing SCI/SCE about 5 seconds) to complete the measurement. 7. View measurement results through Touchscreen, such as Light spectrum, chromatic value, color difference, etc. 8. Data management, comparison, and report generation can be performed using the supporting SQCX quality management software.
• The instrument provides two diameters of reflection and transmission. When using, only one reflection caliber and one transmission caliber can be selected for configuration. • Before measurement, ensure that the instrument has been preheated and calibrated to ensure the accuracy of measurement data. • Operating Ambient Temperature should be in the range of 0~ 40 ° C (32~ 104 ° F), Storage Ambient Temperature should be in the range of -20~ 50 ° C (-4~ 122 ° F). • Please use the designated DC 24V, 3A Power Adapter to power the instrument. • Instrument measurement Repeatability data (such as Delta E * ab within 0.15) is obtained under specific conditions (after instrument preheating correction, the average value of the whiteboard is measured 30 times at intervals of 5s), please pay attention to the conformity conditions during actual measurement. • For transmission measurement, note that the sample capacity matches the selected transmission aperture (φ 8mm or φ 4mm). • Instrument Interface includes USB and Bluetooth ® 5.0, please make sure the connection is stable. • Accessories such as micro printers, instrument inverted test fixtures, culture dishes, etc., can be selected according to actual measurement needs.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.