Using dual-array CMOS image sensors, Repeatability Delta E * ab is controlled within 0.01, Inter-instrument Agreement Delta E * ab is less than 0.12, equipped with four measurement diaMeters, which can measure reflection, transparency and fluorescence samples.
Category : Colorimeter
Brand : 3NH
SKU : NB039087
Service :The delivery and service By NBCLab.Com
Benchtop Colorimeter TS8296 is a Colorimeter developed by 3nh using its own spectroscopic core technology. It adopts a dual-array CMOS image sensor with high Sensitivity and a wide Light spectrum Response range for more accurate testing. TS8296 Benchtop Colorimeter Repeatability Delta E * ab is easily controlled within 0.01, and Inter-instrument Agreement Delta E * ab is controlled within 0.12. The data is stable and reliable, and can be used for accurate analysis and transmission of laboratory Color.
1. Adopt dual array CMOS image sensor with high Sensitivity and wide Light spectrum Response range. 2. Repeatability Delta E * ab is easily controlled within 0.01, Inter-instrument Agreement Delta E * ab is controlled within 0.12, and the data is stable and reliable. 3. Equipped with four measurement diameters of 25.4mm, 15mm, 8mm and 4mm to adapt to more tested samples. 4. Support reflection and transmission measurement, including SCI/SCE Measurement mode and include/exclude UV measurement. 5. Illuminant long life, 5 years more than 3 million measurements. 6. With a variety of Color space, Color difference formula and chroma indicators, comprehensive functions. 7. Equipped with 7-inch TFT true color capacitive Touchscreen, easy to operate. 8. Rich Interface, support USB, Bluetooth ® 5.0 and print serial port.
The instrument adopts concave grating spectroscopy technology to split the light emitted by the 360-780nm combined LED Illuminant and receive it by a 256-pixel dual-array CMOS image sensor. In reflection measurement, D/8 (diffuse illumination, 8 ° direction reception) illumination method is used; in transmission measurement, D/0 (diffuse illumination, 0 ° direction reception) illumination method is used. Various Color parameters of the sample are calculated by analyzing the light spectrum data of the sample reflection or transmission.
Plastic electronics, paints inks, Spinning & weaving garment printing and dyeing, printing and other industries reflection samples, transparent samples Color transfer and quality control; can be used for fluorescence sample measurement.
CIE No.15、GB/T 3978、GB 2893、GB/T 18833、ISO7724/1、ASTM E1164、DIN5033 Teil7
1. Preheat the instrument. 2. Perform instrument calibration. 3. Select the appropriate measurement caliber according to the sample characteristics (reflection or transmission) and size. 4. Select the desired Measurement conditions (e.g. SCI/SCE, Include/Exclude UV, Available Light Sources, etc.). 5. Place samples and make measurements. 6. View and analyze measurement results (Light spectrum, chromatic value, color difference, etc.). 7. Data can be exported or printed through the interface.
* Please use the instrument in an operating environment from 0 to 40 ° C (32 to 104 ° F). * Instrument storage environment is -20~ 50 ° C (-4~ 122 ° F). * Before measurement, ensure that the instrument is fully preheated and corrected to ensure measurement accuracy. * Sample type (reflection, transmission, fluorescence) and size, the correct choice of measurement aperture and Measurement mode. * Maintain instruments regularly to ensure that Optical inspection components are clean. * Power supply with designated DC 24V, 3A Power Adapter.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.