Support conductivity, TDS, salinity, resistivity Multi-ParaMeter measurement, Measurement range of 0.5μS/cm to 200mS/cm. With automatic temperature compensation, automatic identification of 8 standard solutions, Polarographic Dissolved Oxygen ElectRode rapid polarization and 150 sets of Data storage functions, IP57 waterproof design, easy to use in the field and field.
Category : Water Quality Tester
Brand : Yoke
SKU : NB039409
Service :The delivery and service By NBCLab.Com
YOKE P614 is a P6 series conductivity/dissolved oxygen meter for measurement of conductivity, TDS, salinity and resistivity of aqueous solutions, and measurement of dissolved oxygen. Suitable for industrial and mining enterprises, water treatment engineering and environmental protection industries, especially suitable for field and field use.
1. Large LCD display, white backlight controllable. 2. Built-in microprocessor chip, with automatic calibration, automatic temperature compensation, data storage, function settings, automatic shutdown and low voltage display and other intelligent functions. 3. Automatically identify 8 kinds of conductivity standard solutions, there are two series of standard solutions to choose from: European and American series and Chinese series. 4. Measurement mode of dissolved oxygen has the functions of automatic temperature compensation, automatic salinity compensation and manual air pressure compensation. 5. Polarographic Dissolved Oxygen Electrode with new structure Measuring temperature, salinity and dissolved oxygen at the same time, with a dedicated Dissolved Oxygen Electrode calibrating sleeve, Electrode polarization only takes 3 to 5 minutes. 6. Use the combined diaphragm cap. When replacing the sensitive membrane, simply tighten the new diaphragm cap on Electrode, which is very convenient to use. 7. Using excellent conductivity measurement technology, only a little calibrated, equipped with different Electrode constants, to meet the Measurement accuracy requirements of 0.5μS/cm~ 200 mS/cm. 8. Switchable conductivity, TDS, salinity and resistivity. TDS and salinity are calculated using polynomials to ensure full scale conversion accuracy. 9. conductivity Measurement mode has high purity water nonlinear temperature compensation function. 10. Humanized design: bracket design, convenient for customers to use. Non-slip glove design, convenient for customers to operate. 11. The instrument is equipped with Temperature Electrode for automatic temperature compensation. 12. The instrument meets the IP57 waterproof rating, and can be equipped with an optional correction solution and a suitcase.
The instrument has a built-in microprocessor chip and is measured by connecting the conductivity Electrode and the polarographic dissolved Oxygen electrode. The conductivity measurement uses a point calibrating technology and can be automatically adjusted according to the Electrode constant. The dissolved oxygen measurement uses Polarography, Electrode can simultaneously sense temperature, salinity and dissolved oxygen concentration, and perform automatic temperature compensation, automatic salinity compensation and manual air pressure compensation through the microprocessor to output accurate results.
Industrial and mining enterprises, water treatment projects, environmental protection industries, field testing
ISO9001:2000、CE、CMC
1. Install the battery and turn it on. 2. Select the corresponding mode according to the Measurement parameter (conductivity /TDS/salinity/resistivity or dissolved oxygen) and install the corresponding Electrode. 3. Perform calibrating: The conductivity mode can select the standard solution for a little calibrating; the dissolved oxygen mode can use water-saturated air or air-saturated water for Automatic calibration. 4. Immerse the Electrode in the solution to be tested to ensure that the sensitive part of the Electrode is completely submerged. 5. Wait for the reading to stabilize (Dissolved Oxygen Response Time ≤ 30 seconds), record or store the measurement data. 6. Clean Electrode and shut down after use.
• Please ensure that the instrument is used at the specified Ambient Temperature (5~ 35 ° C) and Humidity (≤ 85%). • When conducting conductivity calibrating, please select the correct standard solution series (European, American or Chinese series) according to the region. • Before dissolved oxygen measurement, the Counter electrode needs to be polarized for about 3 to 5 minutes. • When replacing the sensitive film of dissolved Oxygen electrode, please use a special combined diaphragm cap and tighten it. • When performing dissolved oxygen measurement, if you need High Accuracy results, please pay attention to manual pressure compensation. • Although the instrument has an IP57 waterproof rating, it is still necessary to avoid long-term immersion or underwater operation. • When the battery is low, replace the battery in time to ensure Measurement accuracy. When storing data, please note that the number, Measured value, Measurement unit and temperature value will be stored together. • Please use the instrument matching or recommended Electrode for measurement to ensure accuracy requirements.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.