Using 6.5-inch LED screen and Omron long-life buttons, built-in 2000 sets of Data storage, support automatic temperature, salinity, air pressure compensation, polarographic dissolved oxygen ElectRode polarization only takes 3 to 5 minutes.
Category : Water Quality Tester
Brand : Yoke
SKU : NB039436
Service :The delivery and service By NBCLab.Com
YOKE P905 Keypad Operation Benchtop 2-in-1 is an instrument for High Accuracy pH measurement and dissolved oxygen in the laboratory. It is suitable for industries such as biotechnology, aquaculture, power plants and environmental protection, and has wider applications in education and research.
1. Adopt 6.5-inch LED screen, complete parameter display, intuitive, user-friendly interface operation design, convenient for users to operate and use. 2. Adopt Omron long-life light touch Keypad Operation, which is convenient and durable, and can reach more than 100,000 times. 3. Meet the international standard GLP requirements, with Automatic calibration, automatic temperature compensation, data storage, USB output, clock display, wireless printing, function settings and self-diagnostic information and other intelligent functions. 4. The instrument has built-in English Operating system, humanized operation design, and the luminance of the instrument is adjustable. 5. Built-in mass storage can store 2000 sets of measurement data, data can be transferred through U disk storage, storage data can be opened by general office software EXELL, convenient for customers to edit. 6. Measurement mode of dissolved oxygen has the functions of automatic temperature compensation, automatic salinity compensation and automatic air pressure compensation. 7. Polarographic Dissolved Oxygen Electrode with new structure Measuring temperature, salinity and dissolved oxygen at the same time, with a dedicated Dissolved Oxygen Electrode calibrating sleeve, Electrode polarization only takes 3 to 5 minutes. 8. Use the combined diaphragm cap. When replacing the sensitive membrane, simply tighten the new diaphragm cap on Electrode, which is very convenient to use. 9. Automatically identify 15 kinds of pH standard buffer solutions, and there are three series of standard buffer solutions to choose from: European and American series, NIST series and Chinese series. 10. The instrument can be equipped with an optional Bluetooth module, which supports wireless Bluetooth printing, which is convenient for users to operate. 11. Comply with IP54 dust and splash protection grade design.
The instrument is measured by a connected pH Electrode and a polarographic dissolved Oxygen electrode. The pH measurement is based on the relationship between the Electrode potential and the concentration of hydrogen ions in the solution, and has an automatic temperature compensation function. Measuring temperature, salinity and dissolved oxygen at the same time using Polarography, Electrode can automatically compensate for temperature, salinity and pressure through the instrument to obtain accurate dissolved oxygen concentration.
Biotechnology, aquaculture, power plants, environmental protection, education, scientific research
GLP、IP54
1. Turn it on and check the status of the instrument. 2. According to the measurement requirements, connect the corresponding pH Electrode or dissolved Oxygen electrode. 3. For pH measurement, choose the appropriate standard buffer solution series to calibrate. 4. For dissolved oxygen measurement, use a special calibrated sleeve for Electrode polarization (about 3 to 5 minutes), and set the salinity and pressure compensation values as needed. 5. Electrode immersion in the sample to be measured. 6. The instrument automatically displays and stores measurement data (pH, dissolved oxygen, temperature, etc.). 7. After the measurement is completed, the data can be exported through the U disk or wirelessly printed through the optional Bluetooth module.
* Please ensure that the instrument is used under the specified Ambient Temperature (5~ 35 ℃) and Humidity (≤ 85%). * Please read the Electrode instructions carefully before use, and operate and maintain the Electrode correctly, such as regularly changing the diaphragm cap that dissolves Oxygen electrodes. * When pH calibrating, make sure that the buffer solution used is within the valid period and is not contaminated. * When dissolving oxygen measurement, if the sample salinity or local atmospheric pressure is different from the default value, the compensation value needs to be manually entered to ensure the measurement accuracy. The instrument has an IP54 Protection Rating, which is dust- and splash-proof, but not completely waterproof. Do not immerse it in liquids. * Data storage is full (2000 groups), it is recommended to export backups in time to avoid new data overwriting old data. When using the optional Bluetooth printing function, ensure that the printer and instrument are within a valid connection range.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.