Using NDIR Infrared Sensor, Response Time ≤ 20s, Measurement accuracy ≤ +/- 2%. It has a variety of signal output and transmission methods, supports remote monitoring, and has multiple circuit protection functions such as overvoltage and lightning protection.
Category : Gas Detector
Brand : KORNO
SKU : NB039843
Service :The delivery and service By NBCLab.Com
MOT500-CO2-Y series CO2 concentration detector, suitable for CO2 gas concentration detection and analysis in various environments, using non-optical infrared NDIR gas Sensor and microcontroller technology, Response speed, Measurement accuracy, Stability and Repeatability. The instrument adopts a 2.4-inch industrial-grade color screen to fully display various technical indicators and gas concentration values; at the same time, it has a variety of extremely strong circuit protection functions to effectively prevent instrument damage caused by various human factors and uncontrollable factors; the online environment detection platform can be selected. Through a variety of transmission methods, it can be connected to the Municipal Environmental Protection Bureau, Enterprise Services, Central Control Alarm, User Mobile Phone, Baidu Cloud, Alibaba Cloud, etc., and then with powerful Data analysis software, it can realize remote monitoring, remote control, remote alarm, and can perform data real-time query, historical data query, data export, data printing and other operations on user computers, mobile phones, Ipads and other devices.
1. Utilize a new semiconductor nano process for ultra-low power 32-bit microprocessors. 2. Adopt 2.4-inch industrial-grade color screen with a resolution of 320x240. 3. PPM,% VOL, mg/m3 three concentration units can be freely switched. 4. Various signal output options: 4-20mA, RS485, 0-5V, 0-10V, Frequency signal, switching signal. 5. A variety of transmission methods are available: 3-4 core cable, optical fiber, network cable, GPRS transmission, wireless transmission, and video transmission. 6. A variety of data reception methods: user computer, control alarm, PLC, DCS, mobile phone, tablet computer, etc. 7. With status indication function, it comes with 4 sets of LED status indicators. 8. It has the functions of overvoltage protection, lightning protection, short circuit protection, reverse connection protection, anti-static interference, anti-magnetic field interference, etc., and has an automatic recovery function to prevent any external reasons, man-made reasons, natural disasters, etc. from causing instrument damage. 9. With Temperature Humidity detection function, it can detect the temperature Humidity value of gas in the field or pipeline (optional). 10. Full software Automatic calibration, Sensor up to 6 target point Adjustment, ensure the accuracy and linearity of measurement, and have data recovery function. 11. Full Chinese/English operation menu, simple and practical, with temperature compensation function. 12. Optional infrared remote control can be used to remotely operate the instrument without opening the lid.
MOT500-CO2-Y series CO2 concentration detectors use Non-Diffused Infrared (NDIR) gas Sensor and microcontroller technology to detect and analyze CO2 gas concentration. Based on the absorption characteristics of CO2 gas to specific wavelengths of infrared light, the Sensor calculates the gas concentration by measuring the attenuation of Light intensity, and combines the microprocessor for data processing and output to achieve Fast Response and High Accuracy measurement.
Suitable for CO2 gas concentration detection and analysis in various environments.
GB3836.1-2010 "Explosive environments - Part 1: Equipment - General requirements", GB3836.2-2010 "Explosive environments - Part 2: Equipment protected by flameproof enclosures" d "
* Please ensure that the Ambient Temperature is in the range of -30~ 55 ℃, Humidity ≤ 95% RH and no condensation. * Please ensure that the Operating Pressure is within the range of 86~ 120Kpa. * The instrument has the explosion-proof mark ExdII CT6 (flameproof type), please use it in an environment that meets the explosion-proof requirements. * Instrument Protection Rating is IP66, but care should be taken to avoid abnormal flooding or continuous high voltage water Impact. * Please pay attention to the positive cathode when connecting the power supply. The instrument has the function of reverse connection protection, but it is still recommended to connect correctly. * When making electrical connections, please choose the appropriate connector according to the interface specifications (3/4 NPT or 1/2 NPT internal thread). The instrument has a variety of protection functions (overvoltage, lightning protection, short circuit, etc.), but it should still be installed to avoid extreme external conditions as much as possible. * Optional functions (such as Temperature and Humidity Detection, specific transmission mode, secondary alarm, etc.) need to be clear when booking. Periodically calibrated to ensure measurement accuracy. * Do not open the lid without authorization by non-professionals when the instrument is powered on. An infrared remote control can be selected for lid-free setting.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.