Please contact customer service
Adopt equilibrating Conditioning Control system and multi-stage intelligent output to ensure stable temperature and Humidity. Temperature range -40~ 150 ℃, humidity control 20~ 98% RH. With special air circulation system to ensure uniformity, built-in multiple Safety protection and fault self-diagnosis functions.
Category : Temperature Humidity Chamber
Brand : AISRY
SKU : NB040316
Service :The delivery and service By NBCLab.Com
AISRY ASR-80L-40 programmable constant temperature and humidity tester is mainly used to detect the performance of materials in various environments, and test the heat resistance, cold resistance, dry resistance and moisture resistance performance of various materials. The equipment is suitable for mass detection of electronics, electrical appliances, communications, meters, vehicles, plastic products, metals, food, chemicals, building materials, aerospace and other products. It adopts equilibrate Conditioning Control System (BTHC), which transmits the data in the box to the controller through the induction system, and the controller intelligently controls the output power to ensure stable temperature and humidity, and has energy-saving functions.
1. The product has beautiful appearance, reasonable structure, precise process, simple and convenient operation, stable and reliable performance. The controller uses a large color liquid crystal man-machine touch dialog LCD interface, with Chinese and English display, simple operation, and can realize remote control of RS232 computer interface. 3. The refrigeration circulation system adopts the original imported Japanese "Sanyo" brand fully enclosed Compressor (optional from France Taikang Compressor), the key components are imported, and the US environmentally friendly refrigerant is used. 4. Reserve a 50mm diameter test hole on the left side of the box. 5, with automatic, high precision system loop, using P.I.D automatic calculation control, high temperature control accuracy, Stability. 6. Specially designed air circulation circulation and sensing system ensure uniform temperature in the box and avoid dead ends. 7. Adopt enlarged observation window, 4 layers of whole empty tempered Glass, wide field of vision. 8, with a comprehensive protection system, including power overload, leakage, control loop overload short circuit, Compressor, grounding, overtemperature protection, etc., automatically display and stop when the fault.
The equipment adopts equilibrate Conditioning Control System (BTHC). The system collects the actual temperature and humidity data in the test chamber through the sensor and transmits it to the controller. According to the setting program, the controller controls the multi-stage intelligent output such as solid state relay (SSR) to equilibrate the output power of heating, cooling, humidification, dehumidification and other systems, so as to precisely and stably control the environmental conditions in the test chamber. The refrigeration system uses a Compressor forced refrigeration cycle, and cooperates with an energy-saving regulating valve to achieve segmented control; the humidification system uses a split humidifier to avoid freezing; the air circulation system ensures uniform air circulation in the box.
Electronics, electrical appliances, communications, instrumentation, vehicles, plastic products, metals, food, chemicals, building materials, aerospace
Connect the power supply to ensure that the voltage meets the requirements (220V/50HZ, allowing a change of +/- 10%). 2. Perform human-machine interaction through the large color touchscreen of the controller, select or edit the test program. 3, set the required temperature, humidity, time and other parameters, the program can be edited and repeability. 4. Place the sample to be tested on the high-strength stainless steel rack in the box. 5. Close the box door to ensure that the high and low temperature silicone sealing strip is well sealed. 6. Start the test program, the controller will automatically control the operation, and the screen will display the program Linear dispersion and execution status in real time. 7. After the test is completed, the device can be stopped according to the setting to remove the sample. 8. If you need remote control, you can connect to a computer through the RS232 interface for operation.
Equipment should be placed in the environment temperature 0~ 30 ℃, working environment temperature 5~ 25 ℃ conditions. • Miscellaneous items should not be placed within 60CM of the equipment to ensure heat dissipation and air circulation. • When moving the device, please use the high-bearing heavy-duty universal wheel at the bottom to pay attention to stability. • The humidification system uses a built-in water tank or a drawer-type water filling box to add water. Please pay attention to the water quality. The equipment is equipped with an filtrate system to reduce the frequency of clogging. • The equipment has comprehensive protection functions. If there is a failure during operation, the screen will display the fault point. Please do not force it to run before the failure is eliminated. • When conducting low temperature tests, the humidification system adopts a split design to avoid freezing, but it is still necessary to pay attention to the relevant operating conditions. • The standard load of a single layer of the shelf is 20KG, please do not overload it. • There is a test hole reserved on the left side of the equipment, please pay attention to the protection of the wiring harness when using it. • Please disconnect the power supply before long-term use or maintenance.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
