$ 3268.00Ex works
Adopt digestion Colorimetric integrated tube design, detection is safer and more convenient; Minimum display value of 0.001mg/L, Sensitivity is high; Support standard measurement and continuous measurement mode, built-in 4000 sets of data storage, to meet different detection needs.
Category : Water Quality Tester
Brand : TongAo
SKU : NB040419
Service :The delivery and service By NBCLab.Com
TR-308H COD ammonia nitrogen total phosphorus turbidity tester is a water quality testing instrument developed by TONGAO based on HJ/T399-2007, HJ535-2009, GB11893 and GB13200-91 standards. Using imported cold light sources and narrow-band interference technology, the sample Absorbance is detected by Spectrophotometric method, spectrophotometry, and the concentration value (mg/L or degree) is directly displayed after microcomputer treatment. The instrument adopts the design of digestion Colorimetric integrated tube, which has the characteristics of small and portable, fast detection, simple operation and low cost. It is widely used in emergency monitoring, wastewater treatment, chemical industry, food, printing and dyeing industries and research institutions.
1. Wide detection range, can expand dozens of parameters, support customization 2. Sensitivity is high, the minimum display value is 0.001mg/L 3. Imported cold light source, good Optical Property, no need to preheat, life 100,000 hours 4. Intelligent operation program to guide users to complete the operation easily 5. Support standard measurement and continuous Measurement mode, both fast and accurate 6. Low cost of use, low price of consumables, and low usage 7. Colorimetric tube design, safe, simple and fast operation 8. Large-screen LCD display, direct data reading, time-saving operation 9. Compact and portable, light weight, easy to carry 10. Supporting special reagents to reduce user operation 11. Support wireless Bluetooth printing (optional) 12. Can store 4000 sets of historical data 13. Built-in large-capacity lithium battery, power display, long standby 14. Support network port, USB, Bluetooth data transmission 15. Chinese and English interface (optional), user-friendly 16. Built-in system and user programs for easy project search 17. Data storage and power outage protection functions 18. Built-in standard program, no user calibration required 19. Support user-developed programs and reagents 20. Built-in help interface and one-click factory reset function
The instrument is based on the Spectrophotometric method, spectra-trophotometry principle, and adopts imported cold light source and narrow-band interference technology to detect the Absorbance of the sample at a specific light source wavelength. After the data is automatically processed by the microcomputer, the sample concentration value is directly displayed, expressed in mg/L or degrees. Colorimetric integrated tube is used for detection to simplify the operation process.
Emergency monitoring, sewage treatment, chemical industry, wastewater, food, printing and dyeing, R & D institutions, colleges and universities
HJ/T399-2007、HJ535-2009、GB11893、GB13200-91
1. Select the corresponding reagent and digestion Colorimetric integrated tube according to the detection parameters 2. Follow the intelligent operation program to guide the completion of Sample Handling 3. Select Standard measurement or Continuous Measurement mode 4. The instrument automatically detects and displays the concentration value 5. Data can be stored or transmitted via USB, network port, Bluetooth 6. Optional Bluetooth printer to print historical data
• Please read the general precautions of the built-in help interface carefully before use • Ensure that the environment temperature is within the range of 5~ 40 ° C • environment humidity should be ≤ 85% and no condensation • Use matching specialized reagents to ensure detection accuracy • Pay attention to the remaining battery power display and charge it in time • The power supply of the digester can be selected from mobile power supply, vehicle or 220V AC power supply • Pay attention to regular backups when storing data to prevent accidental loss • When users develop their own procedures and reagents, they need to ensure that they meet the testing requirements
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.