Overview
LHS-50CH humidity chamber is a popular Constant Temperature and Humidity Chamber of YIHENG brand. It adopts fluorine-free environmental protection design and has an independent temperature limit alarm system. It automatically interrupts operation over temperature to ensure safety. Humidity Control Range is 80~ 95% RH, Temperature range is 10~ 85 ℃, Input Power is 1450W, Temperature resolution is 0.1 ℃.
Features
1. Adopting a new fluorine-free design, it is environmentally friendly and reliable.
2. Mirror stainless steel liner, four corners and half arcs are easy to clean, and the shelf spacing in the box is adjustable.
3. Microcomputer Temperature Humidity Controller, using TMHM equilibrate Conditioning method, stable operation, precise and safe temperature and humidity control, key components such as controllers and Compressors are imported products.
4. Equipped with an independent temperature limit alarm system, overheating is automatically interrupted to ensure the safety of the experiment.
There is a 25mm diameter test hole on the left side of the box, which is convenient for experimental operation and temperature measurement.
6. Optional recorder to record Temperature and Humidity Linear dispersion.
Principle
Microcomputer Temperature Humidity Controller and TMHM equilibrating Conditioning method are used to ensure the stability of the environment in the box by precisely controlling the temperature and Humidity, and to achieve constant temperature and humidity conditions.
Applications
Spinning & weaving, Food processing and other aseptic tests, Stability inspection, Raw material performance testing of industrial products, Encasement testing, product life testing
Steps
1. Connect the power supply to ensure that the voltage meets the requirements of AC220V50HZ.
2. Set the required temperature Humidity parameters, Temperature range 10~ 85 ℃, Humidity Control Range 80~ 95% RH.
3. Place the sample on the adjustable shelf and adjust the spacing.
4. Start the equipment, monitor the running status, and measure temperature through the test hole if necessary.
5. After the experiment is completed, turn off the power and clean the cabinet.
Notice
• Ambient Temperature should be kept between 5 and 30 ° C to avoid extreme environments affecting performance.
• Power supply voltage must match AC220V50HZ to prevent equipment damage.
• When the temperature exceeds, the system will automatically interrupt, and the parameters need to be checked and reset.
• Regularly clean the liner to maintain hygiene and avoid contaminating the sample.
• Pay attention to safety when using test holes to prevent burns or equipment failure.