Please contact customer service
Pump suction sampling and imported Electrochemical sensor, Response Time ≤ 20 seconds, high detection accuracy, support Data storage and multi-range optional, Protection Rating IP65, suitable for harsh environments.
Category : Gas Detector
Brand : KORNO
SKU : NB040634
Service :The delivery and service By NBCLab.Com
The GT-903 pump suction hydrogen sulfide detector is a Portable single Gas detector, suitable for hydrogen sulfide (H2S) concentration detection in various industrial environments and special environments. The instrument adopts imported Electrochemical sensor and microcontroller technology, with the characteristics of fast Response Speed, High Measurement accuracy, Good Stability and Repeatability, and the whole machine ranks at the domestic professional level of performance. The instrument supports user-defined parameter setting, simple operation, and adopts dust-proof design. It is equipped with dust Filter, which can be used in various harsh situations.
1. Imported electrochemistry Gas Sensor, Fast Response and High Measurement accuracy. 2. The performance of the whole machine ranks at the domestic professional level, with good Stability and Repeatability. 3. Each parameter can be customized by the user, and the operation is simple. 4. The instrument adopts a dust-proof design and is equipped with a dust filter, which is suitable for harsh occasions. 5. Support expansion of 1-4 Sensors (Extended Gas). 6. Equipped with real-time storage and timing storage functions, it can store 120,000 sets of data and view historical data on the screen. 7. Sampling method with pump suction. With explosion-proof certification (CNEx16.0538) and high Protection Rating (IP65). 9. Built-in large capacity 4000mA rechargeable polymer battery. 10. Optional Temperature Humidity Detection Module (Temperature range -40~ 120 ℃, Humidity range 0-100% RH). 11. Provide a variety of optional ranges (0 to 50, 100, 500, 1000, 2000, 5000 ppm).
Electrochemical sensor is used to detect gas concentration. The instrument sucks the environment gas through the built-in sampling pump (pump suction). The gas and the electrolysis liquid in the Sensor undergo oxidation or reduction reaction, generating an electrical signal proportional to the gas concentration. After the signal is processed by the microcontroller, it is converted into a concentration value and displayed. Microcontroller technology ensures Fast Response, High Accuracy and Good Stability.
It is suitable for hydrogen sulfide gas concentration detection in various industrial environments and special environments.
GB3836.1-2010 "Explosive environments - Part 1: Equipment - General requirements", GB3836.4-2010 "Explosive environments - Part 4: Equipment protected by intrinsically safe" i "
1. Check the Appearance and Filter of the Instrument before starting. 2. Press the power button for a long time to turn it on, and the instrument will self-test. 3. Enter the settings interface through the menu key as needed to customize the detection parameters (such as Alarm threshold, storage mode, etc.). 4. Place the sampling Probe in the area to be tested, and the instrument inhales the gas through the built-in pump for detection. 5. Observe the hydrogen sulfide concentration value displayed on the screen in real time. 6. After the detection is completed, press the power button to shut down or wait for the instrument to shut down automatically. 7. Historical storage data can be viewed through the Interface or on-screen menu.
• The instrument should be used in the working environment specified by the product (temperature -30~ 60 ℃, Humidity ≤ 95% RH without condensation, pressure -30Kpa~ 100Kpa). • Avoid instrument impact or prolonged exposure to extreme environments. • Regularly check and clean or replace the Dust Filter to ensure smooth and accurate sampling. • The instrument has an explosion-proof mark, but it still needs to be used in the specified dangerous place. • Please use the matching charger to charge the battery. • If it is not used for a long time, it should be turned on regularly and the battery should be charged and discharged for maintenance. • Sensors have a service life and need to be calibrated or replaced regularly to ensure detection accuracy. • In case of abnormal readings or alarm, appropriate safety measures should be taken immediately and evacuated.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
