Please contact customer service
250L large volume, temperature control accuracy of +/- 0.5 ℃, PID control to ensure that temperature and humidity fluctuations are small. Equipped with an independent temperature limit alarm system, mirror stainless steel liner is easy to clean and supports complex program settings.
Category : Temperature Humidity Chamber
Brand : HuiTai
SKU : NB040869
Service :The delivery and service By NBCLab.Com
HUITAI LHS-250SC + Independent Temperature Limit Alarm System Constant Temperature and Humidity Chamber is a 250L volume constant temperature and humidity environment simulation device. It uses large-screen LCD display and mirror stainless steel liner, Temperature range is 0~ 60 ℃, humidity control range is 60~ 85% RH, PID control to achieve accurate temperature and humidity control, small fluctuation. The box adopts double-decked door structure, good thermal insulation effect, and standard independent temperature limit alarm system to ensure experimental safety.
1. Humanized design: large screen LCD display, menu operation interface; environmentally friendly without fluorine refrigerant; mirror stainless steel liner, four corners and half arcs are easy to clean, shelf spacing is adjustable; double-decked door structure, good thermal insulation performance; optional test hole and door observation window (except some models). 2. Quality assurance: using brand Compressor and self-developed cooling system to prolong service life; using JAKEL circulating fan and unique air duct to ensure temperature uniformity in the box; using international good brand humidity Sensor and built-in water tank electric heating tube humidification system to effectively ensure humidity accuracy; PID Control mode, accurate temperature control and humidity control; with 99 cycles, 30 sections per cycle of complex program operation ability. 3. Safe and reliable: standard independent temperature limit alarm system, automatic interruption of operation and sound and light alarm. 4. Extended function (optional): Optional USB or RS485 interface, connected to a printer or computer, to record temperature parameter changes.
The Constant Temperature and Humidity Chamber precisely adjusts the temperature and humidity in the box through a PID control system. The refrigeration system (without fluorine refrigerant) and the heating system work together to control the temperature, and the built-in water tank electric heating tube humidification system works with the humidity Sensor to control the humidity. The air in the box forms a good circulation through the JAKEL pipe flow circulation fan and the uniquely designed air duct to ensure a uniform and stable environment. When the temperature exceeds the safe range set by the independent temperature limit alarm system, the system will automatically interrupt the operation and issue an alarm.
Spinning & weaving, Food processing and other aseptic tests, Stability inspection, Raw material performance testing of industrial products, Product Encasement testing, Product life testing, Industrial research, Biotechnology testing
The data did not mention specific compliance criteria
1. Connect the AC220V 50HZ power supply. 2. Set the required temperature, humidity, program cycle, and time parameters through the menu-type operation interface of the large-screen LCD display. 3. Put the sample to be tested on the shelf with adjustable spacing in the box. 4, start the equipment operation, the system will automatically control the constant temperature and humidity according to the set parameters. 5. During the experiment, the situation in the box can be viewed through the observation window (optional), or the operation and measurement can be carried out through the test hole (optional). 6. After the experiment is completed or the set time is reached, the equipment stops running and the sample is taken out. 7. It can be optionally connected to a printer or computer to record and export experimental data through the USB/RS485 interface.
Equipment should be used in a non-magnetic and vibration-free environment. ● The performance parameter test conditions are no-load state of environment temperature 20 ℃ and environment humidity 50% RH. ● Power supply voltage is AC220V 50HZ before use. ● Pay attention to the working environment temperature requirements of the equipment (20 ° C). ● The independent temperature limit alarm system is standard, and it will automatically alarm and interrupt the operation when it exceeds the temperature. Please do not disable it at will. ● When cleaning the liner, pay attention to its mirror stainless steel material and four-corner half-arc design. Accessories (such as test holes, observation windows, interfaces, etc.) need to be configured separately according to actual needs. ● Products such as non-standard volume (such as 1000L) can be customized according to user requests.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.