Volume 100 liters, Temperature range -5 to 80 ℃, PID control to ensure that the temperature and humidity fluctuations are small, with 99 cycles of complex program operation ability and independent temperature limit alarm, to ensure the safety and accuracy of the experiment.
Category : Temperature Humidity Chamber
Brand : HuiTai
SKU : NB040871
Service :The delivery and service By NBCLab.Com
HUITAI LHS-100HC humidity chamber is a 100L constant temperature and humidity device with an input power of 1100W and a Temperature range of -5 to 80 ° C. The device features a large-screen LCD display and mirrored stainless steel liner, with double-decked door structure to enhance heat insulation. Its core control system uses PID algorithm to ensure the accuracy and Stability of temperature and humidity control, with small fluctuations.
1. Humanized design: large-screen LCD display, multiple sets of data one-screen display, menu-type operation interface; environmentally friendly without fluorine refrigerant; mirror stainless steel liner, four corners and half arcs are easy to clean, shelf spacing is adjustable; double-decked door structure, good thermal insulation performance; optional test hole and box door observation window. 2. Quality assurance: using brand Compressor and self-developed cooling system to prolong Compressor life; using JAKEL circulating fan and unique air duct to ensure temperature uniformity in the box; using international brand humidity Sensor and built-in water tank electric heating tube humidification system to effectively ensure humidity accuracy; PID Control mode, accurate temperature control and humidity control; with 99 cycles, 30 sections per cycle of complex program operation ability. 3. Standard independent temperature limit alarm system: automatically interrupt operation and sound and light alarm when the temperature exceeds the limit to ensure the safety of the experiment. 4. Optional and convenient data processing function: You can connect a printer or computer through USB or RS485 interface to record temperature parameter changes.
The Constant Temperature and Humidity Chamber precisely adjusts the temperature and humidity in the box through a PID control system. The refrigeration system (with environmentally friendly without fluorine refrigerant) and the heating system work together to achieve precise temperature control. Humidity control is maintained within the set range through an electric heating tube humidification system with a built-in water tank and humidity Sensor feedback. The air in the box is forced to circulate through the JAKEL tube flow circulating fan and a uniquely designed air duct to ensure even distribution of temperature and humidity.
Industrial research, Biotechnology testing, Spinning & weaving, Food processing, Sterility testing, Stability inspection, Raw material performance testing of industrial products, Product Encasement testing, Product life testing
1. Turn on the power supply (AC220V 50HZ). 2. Set the required temperature, humidity and program parameters through the large-screen LCD menu operation interface. 3. Place the sample and adjust the shelf spacing in the box. 4. Start the device to run, and the monitoring screen displays data. 5. After the experiment, shut down the equipment according to the procedures.
● The equipment should be tested under the conditions of environment temperature 20 ℃, environment humidity 50% RH, no strong magnetism and no vibration. Pay attention to the status of the independent temperature limit alarm system to ensure its normal function to ensure safety. ● When cleaning the liner, pay attention to its mirror stainless steel and four-corner half-arc design. Accessories (such as test holes, observation windows, Interfaces, etc.) need to be configured according to actual needs. ● Non-standard volume products can be customized according to user requests. ● The performance parameters are tested based on no-load conditions.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.