500L large capacity, mirror stainless steel liner is easy to clean. Temperature range 0~ 65 ℃, humidity deviation +/- 3~ 5% RH, small fluctuation. With 99 cycle program setting and USB Interface, it is convenient for complex experiments and records.
Category : Temperature Humidity Chamber
Brand : HuiTai
SKU : NB040898
Service :The delivery and service By NBCLab.Com
HUITAI LHS-500SCN + USB interface Constant Temperature and Humidity Chamber is an environment simulation device with precise temperature and humidity control function. It provides various environment simulation conditions required for industrial research and biotechnology testing, and can be widely used in Spinning & weaving, Food processing and other aseptic tests, Stability inspection, and industrial product raw material performance, product Encasement, product life and other tests.
1. Humanized design: large-screen LCD display, menu-style operation interface, simple and easy to understand. 2. Environmental protection and energy saving: use 134a without fluorine refrigerant. 3. Easy to clean and durable: mirror stainless steel liner, four corners and half arc design, box surface sand blasting treatment. 4. Sample protection: The wind speed of the fan can be adjusted in'fast and slow 'gears to prevent the sample from losing moisture too quickly. 5. Structural optimization: The instrument control of the whole machine is placed in the upper left corner of the door panel to save space; double-decked door structure is adopted, which has good thermal insulation. 6. Convenient testing: There is a test hole on the left side of the box, which is convenient for experimental operation and measurement. 7. Reliable core components: brand Compressor, independent research and development of cooling system; JAKEL tube flow circulating fan and unique air duct to ensure temperature uniformity. 8. Temperature and humidity control accuracy: Adopt international good brand humidity Sensor, independently design humidification system, PID Control mode, temperature and humidity control accuracy fluctuation is small. 9. Powerful programming function: a program with 99 cycles, divided into 30 sections per week, each section of 99 hours and 59 minutes of cycle steps. 10. Safety optional: Optional independent temperature limit alarm system, exceeding the limit temperature automatically interrupts and alarms. 11. Easy data processing: standard USB interface, can be connected to a printer or computer, record temperature parameter changes.
The Constant Temperature and Humidity Chamber achieves accurate control and stable maintenance of the temperature and humidity of the environment in the box through the built-in Compressor cooling system, electric heating tube humidification system and circulating fan, combined with PID Control mode and temperature and humidity Sensor. The unique air circulation system ensures the uniformity of temperature and humidity in the box.
Spinning & weaving, Food processing and other aseptic tests, Stability inspection, Raw material performance testing of industrial products, Product Encasement testing, Product life testing, Biotechnology testing, Industrial research
1. Place the device in a suitable location and connect it to a power source. 2. Set the required temperature, humidity, program cycle and other parameters through the large-screen LCD menu operation interface. 3. The shelf spacing in the box and the wind speed gear of the fan can be adjusted according to the experimental needs. 4. Place the sample and close the box door. 5. Start the equipment to run the experiment. 6. During the experiment, the situation in the box can be viewed through the observation window, or measurements can be made through the test hole. 7. After the experiment, the data can be exported by connecting to a computer or printer through a USB interface.
• Power supply voltage of the device is AC220V 50Hz, please make sure the power supply matches. • Please read the operation manual carefully before use and be familiar with the menu interface and function settings. • When placing the sample, pay attention to adjust the shelf spacing to ensure smooth air circulation. • Select the appropriate fan wind speed gear according to the sample characteristics to prevent moisture loss from affecting the experimental results too quickly. • When the equipment is running, do not open the box door frequently, so as not to affect the stability of temperature and humidity in the box. • Note that the Temperature range of the equipment is 0~ 65 ℃, and the humidity control range is 40~ 95% RH. Please do not use beyond this range. • Regularly clean and maintain equipment, especially mirrored stainless steel liners and air ducts. • If experiments with high safety requirements are required, an independent temperature limit alarm system is recommended. When connecting a USB port to export data, make sure your computer or printer is compatible.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.