Please contact customer service
Temperature control accuracy up to +/- 0.2 ℃, humidity deviation +/- 1.5% RH, to ensure accurate and stable test environment. Turbine centrifugal forced air supply and independent steam humidification system, excellent temperature and humidity uniformity, and intelligent defrosting and multiple safety protection functions.
Category : Temperature Humidity Chamber
Brand : TaiSiTe
SKU : NB040931
Service :The delivery and service By NBCLab.Com
Constant temperature and humidity test chamber (WSS-80F) is a kind of equipment used for heat resistance, cold resistance, dry resistance and moisture resistance test. Its temperature control range is 0~ 150 ℃, humidity control range is 20%~ 98% RH, Interior volume is 80L.
1. SUS304 stainless steel studio, flat reaction handle. 2. Vacuum tempered Glass observation window, with defrosting function, easy to observe the experimental situation. 3. Built-in independent steam humidification system, uniform humidity. 4. Using turbine centrifugal forced air supply, the temperature is more uniform. 5. Using the original imported Compressor, environmentally friendly R404 refrigerant, with spray liquid chill down and spray liquid defrost function, stable and effective refrigeration. 6. Built-in pulley, easy to move. 7. Imported large-screen LCD touch controller, supports Chinese and English interface, program editing, real-time temperature Linear dispersion display, and is equipped with USB3.0 or RS485 interface, which can realize remote control. 8. Easy to operate, support fixed-value operation, regular operation, and automatic stop. 9. With auxiliary menu, it can realize over-rise alarm, deviation correction, menu lock and other functions. 10. Equipped with power-off protection, parameter memory, and call recovery functions. 11. Compressor overload protection. 12. Support appointment start stop. 13. With loop self-diagnosis, Sensor fault alarm, upper and lower limit over-temperature alarm function. 14. Intelligent defrosting, monitoring timing, overlift preventer. 15. High safety, with multiple protections such as over-lift alarm, menu lock, over-lift prevention, overload protection, and power-off protection.
The equipment is heated by a nickel-chromium alloy electric heating wire heater, humidified by a stainless steel sheathed heater, and cooled by a cascade refrigeration system driven by a French Taikang or a German BITZER Compressor. A centrifugal fan is used to achieve broadband forced air circulation (up and down) to ensure uniform temperature and humidity in the box. The controller collects data through a PT100 temperature sensor and an imported wet and dry bulb humidity Sensor to perform multi-stage program temperature control to achieve accurate temperature and humidity control.
Electronic and electrical, automobile and motorcycle, aerospace, ship weapons, colleges and universities, R & D institutions and other related products of parts and materials in high temperature, low temperature, heat and humidity environment performance testing
Connect the power supply (AC220V +/- 10% or AC380V/415V +/- 10%). 2. Set the required temperature and humidity program or select the fixed value/timing operation mode through the touch screen controller. 3. Put the sample on the inner shelf and close the box door. 4. Start the equipment and start the experiment. 5. The experimental situation can be observed in real time through the observation window. 6. After the experiment is completed, the device can automatically stop and take out the sample according to the setting.
* Equipment should be placed in a well-ventilated, no direct sunlight, no strong electromagnetic interference environment. Please ensure that the water supply system (pump) is working properly before use to avoid dry burning. * Do not switch the Compressor on and off frequently to avoid affecting the service life. * When the equipment is running, do not open the door frequently, so as not to affect the temperature and humidity Stability and experimental accuracy. Check and clean the condenser regularly to ensure good heat dissipation. Non-professional personnel should not disassemble or modify the safety protection devices of the equipment (such as fuse switches, fuses, over-temperature protectors, etc.). When the equipment malfunctions and alarms, it should be stopped for inspection before use. When moving the device, use the built-in pulley to move smoothly to avoid severe vibration. When not in use for a long time, the power supply should be cut off and a good cleaning and maintenance work should be done.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.