Please contact customer service
Adopt SUS304 stainless steel studio and vacuum tempered Glass observation window, built-in independent steam humidification to ensure uniform humidity. The original imported Compressor is matched with environmentally friendly refrigerant, and the cooling is stable and effective. Temperature control accuracy reaches +/- 0.2 ℃, Temperature Uniformity +/- 1.5 ℃, and has intelligent defrosting, multiple safety protection and remote control functions.
Category : Temperature Humidity Chamber
Brand : TaiSiTe
SKU : NB040940
Service :The delivery and service By NBCLab.Com
The TAISITE WSS-100P constant temperature and humidity test box is a device for heat, cold, dry and moisture resistance experimental testing. Temperature range up to -70 ° C to 150 ° C, humidity control range from 20% to 98% RH, content area of 100L, suitable for a wide range of Reliability testing needs.
1. SUS304 stainless steel studio, equipped with flat reaction handle. 2. Vacuum tempered Glass observation window, with defrosting function, easy to observe the experimental situation at any time. 3. Built-in independent steam humidification system to ensure uniform humidity. 4. The use of turbine centrifugal forced air supply makes the temperature distribution more uniform. 5. Equipped with original imported Compressor, using environmentally friendly R404 refrigerant, with liquid spray chill down and liquid spray defrost function, stable and effective refrigeration. 6. Built-in pulley design, easy to move. 7. Adopt imported large-screen LCD touch controller, support Chinese and English interfaces, real-time display of temperature operation Linear dispersion, and equipped with USB3.0 or RS485 interface to support remote control. 8. Easy to operate, support fixed-value operation, regular operation, and automatic stop. 9. Equipped with dedicated function keys to achieve temperature setting. 10. Auxiliary menu provides over-rise alarm, deviation correction, menu lock and other functions. 11. Equipped with power-off protection, parameter memory, and call recovery functions. 12. The Compressor is equipped with overload protection. 13. Support appointment start stop. 14. With loop self-diagnosis, Sensor fault alarm, upper and lower limit over-temperature alarm function. 15. Support intelligent defrosting, monitoring timing, and over-lift preventer. 16. High security, integrated with multiple safety measures such as over-lift alarm, menu lock, over-lift prevention, overload protection, and power failure protection.
The equipment is heated by a nickel-chromium alloy electric heating wire heater through a multi-stage program temperature control system, and humidified by a stainless steel sheathed heater. The refrigeration system adopts a French Taikang or German BITZER Compressor, uses environmentally friendly R404A and R23 as refrigerants, and achieves rapid cooling through air-cooled single-stage or cascade refrigeration. The centrifugal fan is used in the box with a broadband forced air circulation (up and down) to ensure uniform distribution of temperature and humidity. The humidity control adopts an imported wet and dry bulb Sensor, and the water supply is lifted to the humidification system through a water pump.
Reliability test of electronic products, material weathering resistance test, Stability assessment of chemical products, simulation of storage conditions of pharmaceutical products, environmental adaptability test of auto parts, experimental research of R & D institutions
Connect the power supply (AC220V +/- 10% or AC380V/415V +/- 10%). 2. Set the required temperature and humidity program or select the fixed value/timing operation mode through the touch screen controller. 3. Put the sample to be tested in the inner box and place it on the standard shelf. 4. Start the equipment and start the experiment. 5. Linear dispersion of temperature and humidity can be monitored in real time through the observation window or remotely through the controller. 6. After the experiment reaches the set time or conditions, the equipment can be automatically stopped. 7. After the experiment, remove the sample and perform equipment maintenance as required.
• Power supply voltage meets equipment requirements (AC220V +/- 10% or AC380V/415V +/- 10%). Equipment is equipped with multiple safety protections (e.g. over-temperature protection, anti-dry burning, water shortage protection, etc.), but its effectiveness still needs to be checked regularly. • Pay attention to the size of the inner box (450 * 550 * 450mm), do not overload the sample. • Check the water supply system before use to ensure that the humidification function is normal. • When the equipment is running, do not open and close the door frequently to avoid affecting the uniformity of temperature and humidity. • Maintain equipment regularly, including cleaning and checking key components such as refrigerant and Compressor. • Non-professionals should not disassemble or repair the internal electrical and refrigeration systems of the equipment without authorization.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.