Please contact customer service
Using SUS304 stainless steel studio and imported Compressor, temperature control accuracy of +/- 0.2 ℃, humidity deviation +/- 1.5% RH, with intelligent defrosting, power-off protection and remote control functions.
Category : Temperature Humidity Chamber
Brand : TaiSiTe
SKU : NB040941
Service :The delivery and service By NBCLab.Com
TAISITE WSS-150F constant temperature and humidity test box is a equipment for heat resistance, cold resistance, dry resistance and moisture resistance test. Temperature range is 0~ 150 ℃, humidity control range is 20%~ 98% RH, Interior volume is 150L.
1. SUS304 stainless steel studio, flat reaction handle, vacuum tempered Glass observation window with defrosting function. 2. Built-in independent steam humidification, uniform humidity. 3. Turbine centrifugal forced air supply, more uniform temperature. 4. Original imported Compressor, environmental protection R404 refrigerant, with spray liquid chill down and spray liquid defrost function, stable and effective refrigeration. 5. Built-in pulley, easy to move. 6. Imported large-screen LCD touch controller, Chinese and English optional, real-time display temperature operation Linear dispersion, equipped with USB3.0 or RS485 interface, support remote control. 7. Support convenient operations such as fixed-value operation, regular operation, and automatic stop. 8. With over-rise alarm, deviation correction, menu lock and other auxiliary features. 9. Equipped with power-off protection, parameter memory, and call recovery functions. 10. With Compressor overload protection, loop self-diagnosis, Sensor fault alarm, upper and lower limit over-temperature alarm, intelligent defrosting, monitoring timing, over-lift preventer and other safety and monitoring functions.
The equipment is heated by a nickel-chromium alloy electric heating wire heater, humidified by a stainless steel sheathed heater, and cooled and dehumidified by a refrigeration system driven by a French Taikang or German BITZER Compressor. A centrifugal fan is used to achieve broadband forced air circulation (up and down) to ensure uniform temperature and humidity in the box. The controller precisely adjusts the working state of the heating, humidification and refrigeration system according to the setting program or set value to achieve and maintain the required temperature and humidity environment.
Materials, parts and finished products in the fields of electronics and electricians, automobiles and motorcycles, aerospace, ships and weapons, colleges and universities, R & D institutions, etc. are tested for environmental adaptability such as heat resistance, cold resistance, dry resistance and moisture resistance
Not mentioned
Connect the power supply (AC220V +/- 10% or AC380V/415V +/- 10%). 2. Parameter setting is carried out through imported large-screen LCD touch controller, and fixed-value operation or program operation mode can be selected. 3. Set the required temperature, humidity, running time and other parameters, and can lock the menu. 4. Start the device, the device will run automatically, and the controller will display the temperature operation in real time. Linear dispersion. 5. Remote monitoring and control can be performed via USB 3.0 or RS485 interface. 6. After the operation is completed, the device can be automatically stopped.
• The equipment has a number of safety protection functions (such as over-temperature protection, anti-dry burning protection, water shortage protection, Compressor protection, etc.), but it still needs to be checked regularly. • Please ensure that the water supply system is normal before use to prevent the humidifier from dry burning. • When moving the device, the built-in pulley can be used, but it is necessary to ensure that the ground is flat. • When conducting high and low temperature alternating experiments, please pay attention to whether the defrosting function is normal. • Non-professionals should not modify advanced parameters such as deviation correction in the controller at will. • Call again after the device is powered off, with parameter memory and recovery functions, but it is recommended to confirm the setting value before starting. • Do not block the ventilation port on the back of the device. • The air duct in the box should not be blocked when placing the experimental samples to ensure uniform temperature and humidity.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.