Please contact customer service
Adopt SUS304 stainless steel studio and turbine centrifugal forced air supply, Temperature Uniformity up to +/- 1.5 ℃. Equipped with original imported Compressor and intelligent defrosting function, the cooling is stable and effective, supports remote control and multiple safety protection.
Category : Temperature Humidity Chamber
Brand : TaiSiTe
SKU : NB040943
Service :The delivery and service By NBCLab.Com
Constant temperature and humidity test chamber (WSS series) is used for experimental testing of heat resistance, cold resistance, dry resistance and moisture resistance. Model WSS-150D has an inner product of 150L, uses Temperature range -40~ 150 ℃, humidity control range 20% -98% RH.
1. SUS304 stainless steel studio, flat reaction handle. 2. Vacuum tempered Glass observation window with defrosting function for easy observation. 3. Built-in independent steam humidification, uniform humidity. 4. Turbine centrifugal forced air supply, uniform temperature. 5. Original imported Compressor, environmentally friendly R404 refrigerant, with spray liquid chill down and spray liquid defrost function, stable refrigeration. 6. Built-in pulley, easy to move. 7. Imported large-screen LCD touch controller, Chinese and English optional, programmable, real-time display temperature Linear dispersion, with USB3.0 or RS485 interface to support remote control. 8. Support fixed-value operation, regular operation, and automatic stop. 9. Special function keys to set the temperature, auxiliary menu to achieve over-rise alarm, deviation correction, menu lock. 10. Equipped with power-off protection, parameter memory, and call recovery functions. 11. Compressor overload protection. 12. Support appointment start stop. 13. With loop self-diagnosis, Sensor fault alarm, upper and lower limit over-temperature alarm function. 14. Intelligent defrosting, monitoring timing, overlift preventer. 15. High safety, including over-lift alarm, menu lock, over-lift prevention, overload protection, power failure protection.
The equipment is heated by a nickel-chromium alloy electric heating wire heater, humidified by a stainless steel sheathed heater, and cooled and dehumidified by a refrigeration system driven by a French Taikang or German BITZER Compressor (using R404A, R23 refrigerants). A centrifugal fan is used to achieve broadband forced air circulation (up, out and down) to ensure uniform temperature and humidity in the box. The controller precisely adjusts the working state of the heating, cooling and humidification system according to the set program or fixed value to achieve and maintain the target temperature and humidity environment.
Heat resistance test, cold resistance test, dry resistance test, moisture resistance test
Connect the power supply (AC220V +/- 10% or AC380V/415V +/- 10%). 2. Perform parameter settings (temperature, humidity, running time, etc.) through the touch screen controller, and choose the fixed-value operation or program operation mode. 3. For remote control, it can be connected via USB 3.0 or RS485 interface. 4. Start the device, it will run automatically, and the experimental status can be monitored in the observation window. 5. After the operation is completed, the device can be automatically stopped according to the setting.
• Power supply voltage meets requirements (AC220V +/- 10% or AC380V/415V +/- 10%). • Pay attention to the safety protection functions of the equipment, such as over-temperature protection, anti-dry burning protection, water shortage protection, etc. The equipment will alarm or shut down when abnormal. • Please check whether the water supply of the humidification system is normal before use. • Use the built-in pulley when moving your device and pay attention to safety. • Maintain the refrigeration system regularly to ensure sufficient refrigerant and no leakage. • The controller menu can be locked to prevent misoperation. The equipment has a power-off protection function, and can continue to operate after power is restored, but it is still necessary to pay attention to the continuity of the experiment. • Do not block the entry and exit trend of the equipment to ensure normal air circulation.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.