Adopt SUS304 stainless steel studio and imported Compressor, temperature control accuracy of +/- 0.2 ℃, humidity deviation +/- 1.5% RH, with automatic defrosting, forced air supply and multiple safety protection functions to ensure the stability and reliability of the experimental process.
Category : Temperature Humidity Chamber
Brand : TaiSiTe
SKU : NB040944
Service :The delivery and service By NBCLab.Com
TAISITE WSS-150Q constant temperature and humidity test box is a device for heat resistance, cold resistance, dry resistance and moisture resistance testing. Temperature range covers -20 ℃, -40 ℃, -70 ℃ to 150 ℃, humidity control range is 20% to 98% RH, and provides a variety of content product options, such as 50L, 80L, 100L, 150L, etc.
1. The studio is made of SUS304 stainless steel and is equipped with a flat reaction handle. 2. The observation window adopts vacuum tempered Glass, which has the function of defrosting, which is convenient for real-time observation. 3. Built-in independent steam humidification system to ensure uniform humidity. 4. Adopt a turbine centrifugal forced air supply system to ensure a more uniform temperature distribution. 5. Using the original imported Compressor, using environmentally friendly R404 refrigerant, with liquid spray chill down and spray liquid defrost function, stable refrigeration. 6. Built-in pulley, easy to move. 7. Equipped with imported large-screen LCD touch controller, supports Chinese and English interface, program editing, real-time temperature Linear dispersion display, and has USB3.0 or RS485 interface for remote control. 8. Easy to operate, support fixed-value operation, regular operation and automatic stop. 9. With dedicated function keys for temperature setting, the auxiliary menu provides over-rise alarm, deviation correction, menu lock and other functions. 10. With multiple safety protection functions, including power-off protection, parameter memory, call recovery, Compressor overload protection, appointment start-stop, circuit self-diagnosis, Sensor fault alarm, upper and lower limit over-temperature alarm, intelligent defrosting and over-rise preventer, etc.
The device achieves precise temperature control through a nickel-chromium alloy electric heating wire heater and a refrigeration system (France Taikang or Germany BITZER Compressor). Humidity control is achieved through a steam humidification system generated by a stainless steel sheathed heater. The air in the box is circulated by a broadband forced airflow (up, out, down) through a centrifugal fan to ensure uniform distribution of temperature and humidity. The control system adopts multi-stage program temperature control, and real-time monitoring and feedback are carried out through PT100 temperature sensor and imported wet and dry bulb humidity sensor.
Electronics and electrical engineering, automotive parts, materials research, chemical industry, Biomedical, aerospace, scientific research institutions
Connect the power supply (AC220V +/- 10% or AC380V/415V +/- 10%). 2. Set the required temperature and humidity program or select the fixed value/timing operation mode through the touch screen controller. 3. Start the equipment, the system will run automatically, and the experimental status can be monitored in the observation window. 4. After the experiment, the equipment can be automatically stopped according to the setting, or it can be stopped manually.
• Power supply voltage meets equipment requirements (AC220V +/- 10% or AC380V/415V +/- 10%). • When the equipment is running, do not open the box door frequently, so as not to affect the internal temperature and humidity Stability. • Regularly check the water supply of the humidification system to ensure that the water level is normal and avoid dry burning. • Pay attention to the status of the safety protection device of the equipment, and check in time in case of alarm (such as overtemperature, water shortage, overload, etc.). • When moving your device, use the built-in pulley to move smoothly. • Non-professionals should not disassemble or adjust refrigeration or electrical systems. • When the equipment is not in use for a long time, it is recommended to disconnect the power supply and do a good job of cleaning and maintenance.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.