Temperature range -60~ 150 ℃, humidity control 20~ 98% RH, Temperature Uniformity +/- 1.5 ℃. Adopt SUS304 stainless steel studio, imported Compressor and touch screen controller, with remote control, multiple safety protection and convenient mobile function.
Category : Temperature Humidity Chamber
Brand : TaiSiTe
SKU : NB040949
Service :The delivery and service By NBCLab.Com
Constant temperature and humidity test chamber (WSS-225Q) is a device for heat, cold, dry and humidity environment testing. Temperature range up to -60 ℃ to 150 ℃, humidity control range is 20% to 98% RH, Interior volume is 225L, suitable for a variety of environment simulation test needs.
1. SUS304 stainless steel studio, equipped with flat reaction handle. 2. Vacuum tempered Glass observation window, with defrosting function, easy to observe the experimental status in real time. 3. Built-in independent steam humidification system to ensure uniform humidity. 4. The use of turbine centrifugal forced air supply makes the temperature distribution more uniform. 5. Using the original imported Compressor, environmentally friendly R404 refrigerant, with spray liquid chill down and spray liquid defrost function, stable and efficient refrigeration. 6. Built-in pulley design, easy to move. 7. Equipped with imported large-screen LCD touch controller, supports Chinese and English interface, easy program editing, real-time display temperature operation Linear dispersion, and has USB3.0 or RS485 interface, which can realize remote control. 8. Easy to operate, support fixed-value operation, regular operation, automatic stop and other functions. 9. Special function keys to achieve temperature setting, auxiliary menu supports over-rise alarm, deviation correction, menu lock. 10. Equipped with power-off protection, parameter memory, and call recovery functions. 11. Provide Compressor overload protection, scheduled start and stop, loop self-diagnosis, Sensor fault alarm, upper and lower limit over-temperature alarm and other safety and intelligent functions. 12. Intelligent defrosting, monitoring timing, over-lift preventer design. 13. Multiple safety protection: over-lift alarm, menu lock, over-lift prevention, overload protection, power failure protection.
The equipment is heated by a nickel-chromium alloy electric heating wire heater and humidified by a stainless steel sheathed heater. The refrigeration system adopts a French Taikang or German BITZER Compressor, uses environmentally friendly R404A and R23 refrigerants, and achieves rapid cooling through air-cooled single-stage or cascade refrigeration. The air in the box is circulated through a centrifugal fan and a broadband forced airflow (up, out, down) to ensure uniform distribution of temperature and humidity. The control system collects data through a PT100 temperature sensor and an imported wet and dry bulb humidity Sensor, and performs multi-stage program temperature control by a touch screen controller to achieve accurate environment simulation.
Electronic and electrical engineering, automotive parts, aerospace, materials research, chemical industry, medicine, Encasement, scientific research institutions and other fields that require environment Reliability testing.
No specific criteria were mentioned.
Connect the power supply (AC220V +/- 10% or AC380V/415V +/- 10%). 2. Set the required temperature, humidity and program through the large-screen LCD touch controller. 3. Select the operation mode (e.g. fixed-value operation, regular operation). 4. Start the device and start the test. 5. Monitor the experimental status in real time through the observation window. 6. After the test is completed, the device can be stopped automatically or manually. 7. Data export or remote monitoring can be performed using USB or RS485 interfaces.
• Equipment should be installed in a well-ventilated location without direct sunlight and away from heat sources. • Please ensure that the water supply system (pump) is working normally before use to prevent dry burning. • Do not open and close the box door frequently during the operation of the equipment, so as not to affect the uniformity of temperature and humidity. • Regularly check and clean the equipment to ensure that the air duct is open. • The equipment has multiple safety protections (such as over-temperature, water shortage, overload protection), please check the cause in time when alarming. • Non-professionals should not disassemble or repair the internal parts of the equipment. • When moving your device, use the built-in pulley to move smoothly. • When not in use for a long time, please disconnect the power supply and do a good job of cleaning and maintenance.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.