Please contact customer service
Volume 408L, Temperature range 0~ 150 ℃, Humidity range 20~ 98% RH. Adopt SUS304 stainless steel studio, imported Compressor and touch screen controller, support program editing and remote control, with multiple safety protections.
Category : Temperature Humidity Chamber
Brand : TaiSiTe
SKU : NB040951
Service :The delivery and service By NBCLab.Com
TAISITE WSS-408F constant temperature and humidity test box is a equipment for heat resistance, cold resistance, dry resistance and humidity resistance test. Its internal volume is 408L, the temperature control range is 0~ 150 ℃, and the humidity control range is 20%~ 98% RH, with accurate temperature and humidity control capabilities.
1. SUS304 stainless steel studio, equipped with flat reaction handle. 2. Vacuum tempered Glass observation window, with defrosting function, easy to observe the experimental situation at any time. 3. Built-in independent steam humidification system to ensure uniform humidity. 4. The use of turbine centrifugal forced air supply makes the temperature distribution more uniform. 5. Using the original imported Compressor, environmentally friendly R404 refrigerant, with spray liquid chill down and spray liquid defrost function, stable and effective refrigeration. 6. Built-in pulley, easy to move. 7. Equipped with imported large-screen LCD touch controller, support Chinese and English optional, real-time display of temperature operation Linear dispersion, with USB3.0 or RS485 interface, support remote control. 8. Easy to operate, support fixed-value operation, regular operation, and automatic stop. 9. Dedicated function keys to achieve temperature setting. 10. The auxiliary menu supports over-rise alarm, deviation correction, and menu lock. 11. Equipped with power-off protection, parameter memory, and call recovery functions. 12. Compressor overload protection. 13. Support appointment start stop. 14. With loop self-diagnosis, Sensor fault alarm, upper and lower limit over-temperature alarm function. 15. Intelligent defrosting, monitoring timing, overlift preventer. 16. High safety, including over-lift alarm, menu lock, over-lift prevention, overload protection, and power failure protection.
The equipment is heated by a nickel-chromium alloy electric heating wire heater and humidified by a stainless steel sheathed heater. The refrigeration system adopts a French Taikang or German BITZER Compressor, uses environmentally friendly R404A and R23 refrigerants, and achieves cooling through air-cooled single-stage or cascade refrigeration. The temperature control adopts a multi-stage program temperature control method. Accurate measurement is carried out through the PT100 temperature sensor and the imported wet and dry bulb humidity Sensor, which is displayed and operated by the color LCD touch screen controller. The air circulation system adopts a centrifugal fan with a broadband forced air circulation (up and down) to ensure uniform temperature and humidity in the box.
Heat resistance test, cold resistance test, dry resistance test, moisture resistance test
1. Set the required temperature, humidity and program through dedicated function keys or touch screen. 2. You can choose to run at a fixed value, regularly or in program mode. 3. Start the equipment and monitor the experimental process through the observation window. 4. After the experiment is completed, the device can be stopped automatically or according to the setting. 5. The experimental process can be monitored using a remote control interface (USB3.0 or RS485).
The equipment has a variety of safety protection functions, such as over-temperature protection, anti-dry burning protection, water shortage protection, etc., but it is still necessary to check the water level and various parameter settings before operation. • Use the built-in pulley when moving your device and make sure the ground is level. • Do not block incoming or outgoing trends when the device is running. When conducting a humidity test, ensure that the water supply system is functioning properly. • The device has a menu lock function to prevent misoperation. Please keep the password properly. • The incoming call recovery function of the device will remember the state before the power failure. Please pay attention to confirm the operating parameters after re-powering. • Regularly check and clean equipment to ensure that refrigeration and ventilating systems are unblocked.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.