Please contact customer service
Interior volume 408 liters, Temperature range -40 to 150 degrees Celsius, humidity control range 20% to 98% RH. Using SUS304 stainless steel studio and vacuum tempered Glass observation window, equipped with turbine centrifugal forced air supply system to ensure uniform temperature and humidity, and has intelligent defrosting, power failure protection and a variety of security alarm functions.
Category : Temperature Humidity Chamber
Brand : TaiSiTe
SKU : NB040953
Service :The delivery and service By NBCLab.Com
The TAISITE WSS-408D constant temperature and humidity test chamber is a device for heat, cold, dry and moisture resistance testing. Its temperature control range is -40 ° C to 150 ° C, humidity control range is 20% RH to 98% RH, and the inner volume is 408 liters.
1. SUS304 stainless steel studio, flat reaction handle. 2. Vacuum tempered Glass observation window with defrosting function for easy observation. 3. Built-in independent steam humidification, uniform humidity. 4. Turbine centrifugal forced air supply, more uniform temperature. 5. Using the original imported Compressor, environmentally friendly R404 refrigerant, with liquid spray chilling down and liquid spray defrosting function, stable refrigeration. 6. Built-in pulley, easy to move. 7. Imported large-screen LCD touch controller, supports Chinese and English, program editing, real-time temperature Linear dispersion display, equipped with USB3.0 or RS485 interface, can be remotely controlled. 8. Easy to operate, support fixed-value operation, regular operation, and automatic stop. 9. Special function keys to set the temperature, auxiliary menu to achieve over-rise alarm, deviation correction, menu lock. 10. Equipped with power-off protection, parameter memory, and call recovery functions. 11. Compressor overload protection. 12. Support appointment start stop. 13. With loop self-diagnosis, Sensor fault alarm, upper and lower limit over-temperature alarm function. 14. Intelligent defrosting, monitoring timing, overlift preventer. 15. High safety, with over-lift alarm, menu lock, over-lift prevention, overload protection, power failure protection.
The device uses a nickel-chromium alloy heating wire heater and a centrifugal fan to force air circulation (up, out and down) to achieve temperature control and uniform distribution in the box. Humidity control is achieved by generating steam humidification from a stainless steel sheathed heater. The refrigeration system adopts a French Taikang or German BITZER Compressor, uses environmentally friendly R404A and R23 refrigerants, and achieves rapid cooling through air-cooled single-stage or cascade refrigeration cycles. The control system adopts multi-stage temperature control, and accurate feedback and adjustment are carried out through PT100 temperature sensor and imported wet and dry bulb humidity Sensor.
Electronics and electrical engineering, automotive parts, aerospace, materials research, chemical industry, medicine, biotechnology, scientific research institutes
Connect the power supply (AC220V +/- 10% or AC380V/415V +/- 10%). 2. Set the required temperature and humidity program or select the fixed value/timing operation mode through the large-screen LCD touch controller. 3. Put the test sample into the inner box and place it on the standard shelf. 4. Start the device and start the test. 5. The experimental situation can be observed in real time through the observation window. 6. After the test is completed, the device can be stopped automatically or according to the program settings. 7. Take out the sample and turn off the power of the device.
Equipment should be placed in a smooth, well-ventilated environment. Make sure the water supply system (pump) is normal before use to prevent dry burning or water shortage. • Do not switch the Compressor on and off frequently, so as not to affect the service life. • When the equipment is running, do not open the box door frequently, so as not to affect the uniformity of temperature and humidity and Stability. • Regularly check and clean the equipment to ensure that the air duct is open. • Non-professionals should not disassemble or modify the safety protection device of the equipment (such as fuse switches, fuses, over-temperature protection, etc.). • When the equipment malfunctions and alarms, please read the manual or contact a professional first, and do not force the operation. • When moving your device, use the built-in pulley to push it carefully. • Power supply voltage requirements to ensure matching.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.