Temperature range -60~ 150 ℃, humidity control range 20~ 98% RH, using SUS304 stainless steel studio, vacuum tempered Glass observation window, original imported Compressor and imported large screen LCD touch controller, support remote control.
Category : Temperature Humidity Chamber
Brand : TaiSiTe
SKU : NB040954
Service :The delivery and service By NBCLab.Com
The constant temperature and humidity test chamber (WSS-408Q) is a device for heat, cold, dry and moisture resistance experimental testing. Its temperature control range can reach -60 ° C to 150 ° C, humidity control range is 20% to 98% RH, and the content volume is 408L, which is suitable for a wide range of Reliability testing needs.
1. SUS304 stainless steel studio, equipped with flat reaction handle, sturdy and durable. 2. Vacuum tempered Glass observation window with defrosting function, easy to observe the experimental situation at any time. 3. Built-in independent steam humidification system to ensure uniform humidity. 4. The use of turbine centrifugal forced air supply makes the temperature distribution in the box more uniform. 5. Using the original imported Compressor and environmentally friendly R404 refrigerant, with liquid spray chill down and liquid spray defrost function, stable and efficient refrigeration. 6. Built-in pulley design, easy to move. 7. Equipped with imported large-screen LCD touch controller, supports Chinese and English interface, program editing, real-time temperature Linear dispersion display, and has USB3.0 or RS485 interface, which can realize remote control. 8. Easy to operate, support fixed-value operation, regular operation, automatic stop and dedicated function keys to set the temperature. 9. Auxiliary menu provides over-rise alarm, deviation correction, menu lock and other functions. 10. With multiple safety protection functions, including power-off protection and parameter memory, Compressor overload protection, appointment start-stop, loop self-diagnosis, Sensor fault alarm, upper and lower limit over-temperature alarm, intelligent defrosting, monitoring timing and over-lift prevention device, etc.
The equipment is heated by a nickel-chromium alloy electric heating wire heater and cooled by a cascade refrigeration system driven by a French Taikang or German BITZER Compressor. The humidity control uses a stainless steel sheathed heater to generate steam humidification. The air in the box is circulated by a wide-band forced airflow through a centrifugal fan (up and down) to ensure uniform distribution of temperature and humidity. The control system collects data through a PT100 temperature sensor and an imported wet and dry bulb humidity Sensor, and is precisely regulated by a multi-stage program by a touch screen controller.
Reliability test of electronic products, material weathering resistance test, high and low temperature heating and humidity test of parts, R & D institution environment simulation, product mass verification
The data did not mention specific compliance criteria.
Connect the power supply (AC220V +/- 10% or AC380V/415V +/- 10%). 2. Set the required temperature and humidity program or select the fixed-value operation mode through the touch screen controller. 3. For remote monitoring, it can be connected via USB or RS485 interface. 4. Place the sample on the shelf. 5. Start the device and run the experiment. 6. During the experiment, real-time observations can be made through the observation window. 7. After the experiment reaches the set time or conditions, the equipment can be automatically stopped. 8. After the experiment, remove the sample and turn off the equipment.
• Make sure the equipment is well grounded and use a Power supply voltage that meets specifications. • When the equipment is running, do not open and close the box door frequently, so as not to affect the stability of temperature and humidity in the box. • Pay attention to check the water supply system to prevent dry burning, and the equipment has the function of water shortage protection. • Do not place flammable, explosive, volatile or corrosive items in the equipment. • Regularly clean the inside of the equipment and the condenser to ensure good ventilated heat dissipation. • The equipment has multiple alarm protection functions. If an alarm is triggered, please check and troubleshoot according to the prompts before running. • When moving the device, use the bottom pulley to move smoothly.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.