Please contact customer service
The studio is made of SUS304 stainless steel and equipped with vacuum tempered Glass observation window. Temperature control accuracy reaches +/- 0.2 ℃, Temperature Uniformity +/- 1.5 ℃. Original imported Compressor and turbine centrifugal forced air supply are used to ensure stable and uniform temperature and humidity.
Category : Temperature Humidity Chamber
Brand : TaiSiTe
SKU : NB040961
Service :The delivery and service By NBCLab.Com
Constant temperature and humidity test box (model WSS-1000F) is a equipment for heat resistance, cold resistance, dry resistance and moisture resistance experimental testing. Temperature range can reach -70~ 150 ℃, humidity control range is 20% -98% RH, content volume is 1000L, with accurate temperature and humidity control ability.
1. SUS304 stainless steel studio, equipped with flat reaction handle and vacuum tempered Glass observation window, with defrosting function, easy to observe. 2. Built-in independent steam humidification system to ensure uniform humidity. 3. Adopt a turbine centrifugal forced air supply system to make the temperature distribution more uniform. 4. Equipped with the original imported Compressor, using environmentally friendly R404 refrigerant, with liquid spray chill down and liquid spray defrost function, stable and effective refrigeration. 5. Built-in pulley design, easy to move. 6. Adopt imported large-screen LCD touch controller, support Chinese and English interface, easy program editing, real-time display temperature operation Linear dispersion, and equipped with USB3.0 or RS485 interface, can realize remote control. 7. Easy to operate, support fixed-value operation, regular operation, and automatic stop. 8. With dedicated function keys for temperature setting, the auxiliary menu supports over-rise alarm, deviation correction, and menu lock. 9. Provide multiple safety protection, including power failure protection (parameter memory, call recovery), Compressor overload protection, scheduled start and stop, loop self-diagnosis, Sensor fault alarm, upper and lower limit over-temperature alarm, intelligent defrosting, monitoring timing and over-lift prevention device.
The equipment is heated by a nickel-chromium alloy electric heating wire heater and humidified by a stainless steel sheathed heater. The refrigeration system adopts a French Taikang fully hermetic or a German BITZER semi-hermetic Compressor, with environmentally friendly R404A and R23 refrigerants, and achieves cooling through air-cooled single-stage or cascade refrigeration. The air in the box is circulated through a centrifugal fan in a broadband forced airflow (up and down) to ensure uniform temperature and humidity. The control system adopts multi-stage temperature control, and accurate feedback and adjustment are carried out through a PT100 temperature sensor and an imported wet and dry bulb humidity Sensor.
Heat resistance test, cold resistance test, dry resistance test, moisture resistance test
Connect the power supply (AC220V +/- 10% or AC380V/415V +/- 10%). 2. Set the required temperature, humidity and operating procedures through the large-screen LCD touch controller (support setting or timing operation). 3. Confirm that the water supply system (pump lift) is normal and ensure that the humidification function is available. 4. Place the sample in the studio and close the box door. 5. Start the equipment, monitor the experimental process through the observation window, and the controller can display the temperature operation in real time. Linear dispersion. 6. After the experiment is completed, the equipment can be stopped automatically or manually. 7. For remote control, it can be operated through a USB 3.0 or RS485 interface connection.
Equipment should be placed in a smooth, well-ventilated environment. • Power supply voltage check before use (AC220V +/- 10% or AC380V/415V +/- 10%). • Ensure that the water supply system has sufficient water sources to avoid dry burning or water shortage operation. • Do not open and close the box door frequently when the equipment is running, so as not to affect the uniformity of temperature and humidity. • Regularly check and clean the equipment to ensure that the ventilator and Sensor are unobstructed and free of contamination. • The equipment has multiple safety protections (such as over-temperature, overload, power-off protection, etc.). If the alarm is triggered, please check the cause before resetting the operation. • Non-professionals should not disassemble or modify the internal electrical and refrigeration components of the equipment. • When moving the device, use the built-in pulley to move smoothly to avoid violent vibration.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.