Please contact customer service
Volume up to 1000L, Temperature range -20~ 150 ℃, Humidity range 20-98% RH. Using SUS304 stainless steel studio, imported Compressor and touch screen controller, with program editing, remote control and multiple safety protection functions.
Category : Temperature Humidity Chamber
Brand : TaiSiTe
SKU : NB040962
Service :The delivery and service By NBCLab.Com
Constant temperature and humidity test chamber (WSS-1000T) is a device for testing heat, cold, dry and humidity environments. Temperature range of -20 ℃ to 150 ℃, humidity control range of 20% to 98% RH, Interior volume of 1000L, suitable for a wide range of Reliability testing needs.
1. SUS304 stainless steel studio, equipped with flat reaction handle. 2. Vacuum tempered Glass observation window, with defrosting function, easy to observe the experimental situation at any time. 3. Built-in independent steam humidification system to ensure uniform humidity. 4. The use of turbine centrifugal forced air supply makes the temperature distribution more uniform. 5. Equipped with original imported Compressor, using environmentally friendly R404 refrigerant, with liquid spray chill down and liquid spray defrost function, stable and effective refrigeration. 6. Built-in pulley design, easy to move. 7. Adopt imported large-screen LCD touch controller, support Chinese and English interfaces, real-time display of temperature operation Linear dispersion, and equipped with USB3.0 or RS485 interface to support remote control. 8. Easy to operate, support fixed-value operation, regular operation and automatic stop function. 9. Special function keys to achieve temperature setting, auxiliary menu provides over-rise alarm, deviation correction, menu lock and other functions. 10. With multiple safety protection functions, including power-off protection, parameter memory, call recovery, Compressor overload protection, appointment start and stop, circuit self-diagnosis, Sensor fault alarm, upper and lower limit over-temperature alarm, intelligent defrosting, monitoring timing and over-lift prevention device, etc.
The equipment is heated by a nickel-chromium alloy electric heating wire heater and humidified by a stainless steel sheathed heater. The refrigeration system adopts a French Taikang or German BITZER Compressor with environmentally friendly refrigerants R404A and R23 to achieve rapid cooling through air-cooled single-stage or cascade refrigeration. The centrifugal fan is used in the box with a broadband forced air circulation (up-out-down-in) mode to ensure uniform distribution of temperature and humidity. The control system collects data through the PT100 temperature sensor and imported wet and dry bulb humidity Sensor, and performs accurate temperature and humidity control by multi-stage program.
Reliability test of electronic products, material weathering resistance test, environment simulation of auto parts, Stability inspection of pharmaceutical products, performance evaluation of chemical products
Connect the power supply (AC220V +/- 10% or AC380V/415V +/- 10%). 2. Set the required temperature and humidity program or select the fixed value/timing operation mode through the touch screen controller. 3. Place the test sample in the inner box and place on the standard shelf. 4. Start the device and run the test program. 5. During the test, the sample status can be monitored in real time through the observation window. 6. After the test is completed, the device can automatically stop, remove the sample, and turn off the power.
* The equipment should be installed on a well-ventilated, smooth ground without direct sunlight. Please ensure that the water supply system is normal before use to avoid dry burning. Do not open and close the box door frequently when the equipment is running, so as not to affect the uniformity of temperature and humidity. * Regularly check and clean the equipment filtrate network to ensure smooth wind circulation. When the equipment malfunctions and alarms, please read the manual or contact a professional first, and do not disassemble it yourself. When handling, please use the built-in pulley to avoid violent vibration. When not in use for a long time, please disconnect the power supply and do a good job of cleaning and maintenance.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.