Please contact customer service
1000L large-capacity studio, Temperature Uniformity +/- 1.5 ℃, using turbine centrifugal forced air supply and independent steam humidification system to ensure stable temperature and humidity, equipped with imported Compressor and intelligent controller to support program editing and remote monitoring.
Category : Temperature Humidity Chamber
Brand : TaiSiTe
SKU : NB040964
Service :The delivery and service By NBCLab.Com
Constant temperature and humidity test chamber (WSS-1000Q) is a device for heat, cold, dry and moisture resistance experimental testing. Temperature range of -60 ℃ to 150 ℃, humidity control range of 20% to 98% RH, content volume of 1000L, suitable for a wide range of Reliability testing needs.
1. The studio is made of SUS304 stainless steel and is equipped with a flat reaction handle. 2. The observation window adopts vacuum tempered Glass, which has the function of defrosting, which is convenient for real-time observation. 3. Built-in independent steam humidification system to ensure uniform humidity. 4. Using turbine centrifugal forced air supply, the temperature distribution is more uniform. 5. Using the original imported Compressor, environmentally friendly R404 refrigerant, with liquid spray chilling down and liquid spray defrosting function, stable refrigeration. 6. Built-in pulley design, easy to move. 7. Equipped with imported large-screen LCD touch controller, supports Chinese and English interface, program editing, real-time temperature Linear dispersion display, and has USB3.0 or RS485 interface for remote control. 8. Easy to operate, support fixed-value operation, regular operation, and automatic stop. 9. Special function keys to achieve temperature setting, auxiliary menu provides over-rise alarm, deviation correction, menu lock and other functions. 10. With multiple safety protection: power-off protection and parameter memory, Compressor overload protection, scheduled start and stop, loop self-diagnosis, Sensor fault alarm, upper and lower limit over-temperature alarm, intelligent defrosting, over-rise prevention device, etc.
The equipment is heated by a nickel-chromium alloy electric heating wire heater, humidified by a stainless steel sheathed heater, and cooled and dehumidified by a cascade refrigeration system driven by a French Taikang or German BITZER Compressor. A centrifugal fan is used for broadband forced air circulation (up and down) to ensure uniform temperature and humidity in the box. The control system collects data through the PT100 temperature sensor and imported wet and dry bulb humidity Sensor, and the touch screen controller performs multi-stage program temperature control to achieve accurate temperature and humidity environment simulation.
Reliability test of electronic products, material weathering resistance test, environment simulation of auto parts, Stability inspection of pharmaceutical products, performance evaluation of chemical products
Not mentioned
Connect the power supply (AC220V +/- 10% or AC380V/415V +/- 10%). 2. Set the required temperature, humidity and program through the large-screen LCD touch controller. 3. Select the operation mode (e.g. fixed-value operation or regular operation). 4. Start the equipment and monitor the experimental process through the observation window. 5. After the experiment is completed, the device can be stopped automatically or manually.
Equipment should be installed in a well-ventilated place without direct sunlight. • Please check the water supply system before use to ensure that the water source is sufficient to prevent dry burning or water shortage protection triggering. • Do not frequently open and close the box door when the equipment is running, so as not to affect the uniformity of temperature and humidity and the experimental accuracy. • Regularly inspect and clean equipment, especially air ducts and Sensor areas. • Equipment is equipped with multiple safety protection devices (such as over-temperature, over-current, over-voltage protection), please check the cause in time when alarming, and non-professionals should not disassemble and repair by themselves. • When moving the device, use the built-in pulley to move smoothly to avoid violent vibration. • When not in use for a long time, please disconnect the power supply and drain the humidification system to store water.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.