High Accuracy Control of Temperature +/- 0.1 ℃ and Humidity +/- 1% R.H. with equilibrate Conditioning Control system and 9 sets of PID paraMeters. Refrigeration system with imported Compressor and environmental friendly refrigerant, as well as specially designed air circulation system, ensure uniform and stable temperature and Humidity in the box.
Category : Temperature Humidity Chamber
Brand : AISRY
SKU : NB040986
Service :The delivery and service By NBCLab.Com
AISRY ASR-50L-40 programmable constant temperature and humidity testing machine is a testing equipment used to simulate various temperature and humidity environments. It is mainly used to detect the performance of materials in various environments and test the heat resistance, cold resistance, dry resistance and moisture resistance of various materials. The equipment adopts the equilibrate Conditioning control system, which ensures the stability of temperature and humidity in the box through intelligent control and has the function of energy saving.
1. The product has beautiful appearance, reasonable structure, precise process, simple and convenient operation, stable and reliable performance. The controller uses a large color liquid crystal man-machine touch dialog LCD interface, with Chinese and English display, simple operation, and can realize remote control of RS232 computer interface. 3. The refrigeration circulation system adopts the original imported Japanese "Sanyo" brand fully enclosed Compressor (purchased from France Taikang Compressor), the key components are imported, and the refrigerant adopts American environmentally friendly refrigerant. 4. Reserve a 50mm diameter test hole on the left side of the test chamber. 5, with automatic, high precision system loop, using P.I.D automatic calculation control, temperature control with High Accuracy and High Stability. 6. Specially designed air circulation system and sensing system ensure uniform temperature in the box and avoid dead ends. 7. Adopt enlarged observation window, 4 layers of whole empty tempered Glass, wide field of vision. 8, with a comprehensive protection system, including power overload, leakage, control loop overload, short circuit, Compressor, grounding, over-temperature protection and alarm prompts, etc., automatically display and stop when the fault. 9. The heating system uses multi-stage high-temperature and corrosion-resistant alloy heating tubes, coupled with PID modules, to ensure stable temperature and energy saving. 10. The humidification system adopts a circular split humidifier to avoid freezing at low temperature; the humidification tube is made of special alloy, which can be protected by dry burning; it has a water circulation system that saves 40% of water, and the water quality filtrate system reduces the frequency of clogging. 11. The air circulation system uses high-resistance motors and multi-wing fan blades. 12, the refrigeration system adopts imported copper pipeline, which has good flexibility and good shock absorption effect. 13, the controller is imported 7-inch color touch screen, temperature and humidity programmable, high accuracy, with program editing, Linear dispersion display, power-off memory, fault prompt and other functions.
The device adopts the equilibrate Conditioning control system. The induction system transmits the actual temperature and humidity data in the test chamber to the controller. The controller performs multi-stage intelligent output by controlling the solid state relay (SSR), equilibrating the output power of the temperature and humidity system, so as to ensure that the temperature and humidity in the test chamber are fully stable. The system also has the function of energy saving, which can reduce the power of the instrument to a greater extent and ensure the long-term accurate and stable operation of the instrument.
Electronics, electrical appliances, communications, instruments, vehicles, plastic products, metals, food, chemicals, building materials, aerospace and other products testing mass
GB5170,2,3,5,6-95 "Environmental test basic parameter method of verification high temperature, constant heat and humidity, alternating humidity cabinet test equipment", GB 2423.2-89 (IEC68-2-2), GB/T 2423.3-93 (IEC68-2-3), GB/T423.4-93 (IEC68-2-30)
1. Ensure that there are no Miscellaneous items within 60CM of the instrument, and the installation ground is not seriously tilted. Connect the power supply (220V/50HZ), and note that the allowable voltage fluctuation is +/- 10%. 3. Add water to the built-in water tank through the drawer type water box. 4. Set the required temperature and humidity program Linear dispersion on the controller (7-inch color touch screen), which can be edited, cleared, and inserted into the program segment. 5. Place the sample to be tested on the shelf in the box. 6. Start the device, the controller will automatically execute the setting program and display the Linear dispersion execution status in real time. 7. During the test, the sample can be viewed through the observation window, or the external test harness can be connected through the left test hole. 8. After the test is completed, the device can be stopped according to the setting to remove the sample. 9. The device has a power-off program memory function, which can automatically start and continue to execute the program after power-back.
* The recommended environment temperature is 0~ 30 ℃ (working environment temperature 5~ 25 ℃). * Miscellaneous items cannot be placed within 60CM of the instrument. The installation ground must not be severely tilted. * Power supply voltage requirements and variation range. * When adding water, use the drawer-type water filling box provided by the equipment and use its water quality to filtrate the system. * The equipment has a comprehensive protection system. When there is a failure, the screen will display the fault point and cause and automatically shut down. Please check according to the prompts. * Shelves have a maximum load-bearing limit (20KG), please do not overload. * For low temperature testing, the circular split humidifier can avoid freezing in the sink, but it is still necessary to pay attention to the operating status. Regular maintenance and inspection of refrigeration systems, humidification systems, and other components.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.