Humidity control accuracy of +/- 0.1 ℃ and +/- 1% R.H. Equipped with imported Compressor and environmental protection refrigerant, equipped with 7-inch color Touchscreen controller, supports program editing and remote control.
Category : Temperature Humidity Chamber
Brand : AISRY
SKU : NB040987
Service :The delivery and service By NBCLab.Com
AISRY ASR-50L-20 programmable constant temperature and humidity testing machine is a testing equipment used to simulate various temperature and humidity environments. It is mainly used to detect the performance of materials in various environments and test the heat resistance, cold resistance, dry resistance and moisture resistance of various materials. It adopts equilibrate Conditioning Control System (BTHC), which transmits the data in the box to the controller through the induction system, and the controller intelligently adjusts the output power to ensure stable temperature and humidity and has energy-saving functions.
1. The product has beautiful appearance, reasonable structure, precise process, simple and convenient operation, stable and reliable performance. The controller uses a large-scale color liquid crystal man-machine touch dialog LCD interface, which is displayed in both Chinese and English. It is easy to operate, easy to learn, stable and reliable, and can be remotely controlled by an RS232 computer interface. 3. The refrigeration circulation system adopts the original imported Japanese "Sanyo" brand fully enclosed Compressor (purchased from France Taikang Compressor), the core components are imported, and the refrigerant adopts American environmentally friendly refrigerant. 4. Reserve a 50mm diameter test hole on the left side of the test chamber. 5, with automatic, high precision system loop, using P.I.D automatic calculation control, temperature control with High Accuracy and High Stability. 6. Specially designed air circulation circulation and sensing system ensure uniform temperature in the box and avoid dead ends. 7. Adopt enlarged observation window, 4 layers of whole empty tempered Glass, wide field of vision. 8, with a comprehensive protection system, including power overload, leakage, control loop overload short circuit, Compressor, grounding, overtemperature protection, etc., the screen automatically displays and stops when the fault. 9. The heating system uses multi-stage high-temperature and corrosion-resistant alloy heating tubes, coupled with PID modules, to ensure stable temperature and energy saving. 10. The humidification system adopts a circular split humidifier to avoid freezing at low temperature; the humidification tube is made of special alloy, which can be dry burned and protected; the built-in water tank, drawer type water addition, convenient and beautiful; it has a water circulation system that saves 40% water and a water quality filtrate system. 11. The air circulation system uses high-resistance motors, multi-wing fan blades, and specially designed forced air circulation. 12, the refrigeration system adopts imported copper pipeline, which has good flexibility and good shock absorption effect. 13, the controller is imported 7-inch color touch screen, temperature and humidity can be programmed at the same time, high accuracy, with program editing, graphic Linear dispersion display, power-off memory, fault prompt and other functions.
The device adopts equilibrate Conditioning Control System (BTHC). The induction system transmits the actual temperature and humidity data in the test chamber to the controller, and the controller performs multi-stage intelligent output by controlling the solid state relay (SSR), thereby equilibrating the heating, cooling, humidification, dehumidification and other output power of the temperature and humidity system to ensure that the temperature and humidity in the test chamber are fully stable. The system also has an energy-saving function, which can reduce the power of the instrument to a greater extent and ensure long-term accurate and stable operation.
Electronics, electrical appliances, communications, instruments, vehicles, plastic products, metals, food, chemicals, building materials, aerospace and other products testing mass
GB5170,2,3,5,6-95 "Environmental test basic parameter method of verification high temperature, constant heat and humidity, alternating humidity cabinet test equipment", GB 2423.2-89 (IEC68-2-2), GB/T 2423.3-93 (IEC68-2-3), GB/T423.4-93 (IEC68-2-30)
1. Ensure that the instrument is installed in an environment that meets the requirements (there are no items within 60cm around, and the ground is not seriously inclined). Connect the power supply (220V/50HZ), and note that the allowable voltage fluctuation is +/- 10%. 3, through the imported 7-inch color touch screen controller for human-machine interaction operation. 4. Select or edit the required temperature and humidity test program on the controller (up to 120 sets of programs). 5. Set the temperature and humidity value and running time for each program segment. 6. After confirming the parameters, start the test program. 7. During the test, the sample can be viewed through a large window, or an external test harness can be connected through the left test hole. 8. After the test is completed, the device is stopped according to the program or manually. 9. Check the test data and Linear dispersion displayed by the controller.
* The operating environment temperature is 0~ 30 ℃, and the working environment temperature is recommended to be 5~ 25 ℃. Miscellaneous items cannot be placed within 60CM of the instrument to ensure heat dissipation and air circulation. The installation ground must not be severely tilted. * Power supply voltage requirements and variation range. * Make sure there is water in the humidification system tank before use, and regularly check the water quality to filtrate the system. The equipment has a variety of protection functions. When a fault alarm occurs, please check the fault point and cause displayed on the screen first, and then run it after troubleshooting. Non-professional personnel should not disassemble or repair the internal components of the equipment. When placing test samples, please pay attention to the load-bearing capacity of the rack (up to 20KG) and distribute it reasonably to ensure uniform airflow in the box. * When conducting low temperature tests, the humidification system adopts a split design to avoid freezing, but it is still necessary to pay attention to the operating status. When the equipment is not in use for a long time, it is recommended to disconnect the power supply and do a good job of cleaning and maintenance.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.