Adopt equilibrate Conditioning Control system, Temperature range -20~ 150 ℃, humidity control 20~ 98% RH. With automatic PID calculation control, Temperature Uniformity +/- 1.5-2 ℃, built-in multiple Safety protection system to ensure long-term stable operation.
Category : Temperature Humidity Chamber
Brand : AISRY
SKU : NB040990
Service :The delivery and service By NBCLab.Com
AISRY programmable constant temperature and humidity testing machine (model: ASR-150L-20) is mainly used to test the performance of materials in various environments, test their heat resistance, cold resistance, dry resistance and moisture resistance performance. The equipment adopts equilibrate Conditioning Control System (BTHC), which intelligently adjusts the output power through the controller to ensure the stability of temperature and humidity in the box. It has energy saving function and is suitable for electronics, electrical appliances, communications, meters, vehicles, plastic products, metals, food, chemicals, building materials, aerospace and other products for mass detection.
1. The product has beautiful appearance, reasonable structure, precise process, simple and convenient operation, stable and reliable performance. The controller uses a large color liquid crystal man-machine touch dialog LCD interface, with Chinese and English display, simple operation, and can realize remote control of RS232 computer interface. 3. The refrigeration circulation system adopts the original imported Japanese "Sanyo" brand fully enclosed Compressor (purchased from France Taikang Compressor), the core components are imported, and the American environmentally friendly refrigerant is used. 4. A 50mm diameter test hole is reserved on the left side of the test chamber. 5, with automatic, high precision system loop, using P.I.D automatic calculation control, high temperature control accuracy, Stability. 6. Specially designed air circulation circulation and sensing system ensure uniform temperature in the box and avoid dead ends. 7. Adopt enlarged observation window, 4 layers of whole empty tempered Glass, wide field of vision. 8, with a comprehensive protection system, including power overload, leakage, Compressor, overtemperature protection, when the fault screen automatically displayed and shut down.
The equipment adopts equilibrate Conditioning Control System (BTHC). The system transmits the actual temperature and humidity data in the test chamber to the controller through the Sensor. The controller controls the solid state relay (SSR) to equilibrate the output power of the heating, cooling, humidification, dehumidification and other systems in a multi-stage intelligent output mode, so as to ensure the full stability of the temperature and humidity in the test chamber. The system has an energy-saving function, which can reduce the power used and ensure the long-term accurate and stable operation of the instrument.
Electronics, electrical appliances, communications, instrumentation, vehicles, plastic products, metals, food, chemicals, building materials, aerospace
1. Preparation: Ensure that the power supply of the equipment meets the requirements (220V/50HZ), the working environment temperature is between 5 and 30 ° C, and there are no Miscellaneous items within 60CM around the equipment. 2. Power on: Connect the power supply and turn on the air switch. 3. Parameter settings: Through the 7-inch color touch screen controller, select the Chinese/English interface, enter the program editing screen, and set the required temperature and humidity program Linear dispersion, segment, time and cycle times. 4. Place the sample: Open the box door, place the sample on the stainless steel shelf (standard 1 layer, up to 4 layers), and close the box door. 5. Start test: After confirming that the program is correct on the controller, start the test. The device will run automatically, and the screen will display the execution status of the program Linear dispersion in real time, the current temperature and humidity and the remaining time. 6. Monitoring and completion: The test process can be viewed through the observation window, and the equipment has the function of automatic alarm and shutdown. After the test is completed, the equipment stops running and samples are taken out. 7. Shut down: Turn off the power of the device.
* The environment temperature is recommended to be 5~ 25 ° C to ensure that the equipment is well ventilated, and Miscellaneous items cannot be placed within 60CM. * Power supply voltage of the equipment is 220V/50HZ, the allowable change value is +/- 10%, and the grounding is reliable. * The humidification system adopts a drawer type water box, please use the water after filtrating, and regularly check the water quality of the filtrating system. When placing the sample, do not exceed the load limit of 20KG on a single shelf, and ensure that the sample placement does not affect the internal air circulation. When the equipment is running, do not open and close the box door frequently to avoid affecting the temperature and humidity stability and test results. * The device has comprehensive protection functions. If there is a fault alarm and shutdown, please check the fault information displayed on the screen first, troubleshoot and then restart. Non-professionals should not disassemble or modify the internal components of the equipment, especially the refrigeration system piping. * Regular maintenance, such as cleaning the condenser, checking the sealing strip, etc., to ensure the long-term stable operation of the equipment.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.