Please contact customer service
Adopt equilibrate Conditioning Control system to achieve High Accuracy Control of Temperature Fluctuation +/- 0.5-1 ℃ and Humidity deviation +/- 1~ 2%. Equipped with imported Compressor and environmentally friendly refrigerant, with multi-stage heating and energy saving functions, and built-in comprehensive protection system to ensure safe and reliable operation.
Category : Temperature Humidity Chamber
Brand : AISRY
SKU : NB041002
Service :The delivery and service By NBCLab.Com
AISRY ASR-1000L-60 programmable constant temperature and humidity tester is mainly used to test the performance of materials in various environments, and test the performance of heat resistance, cold resistance, dry resistance and moisture resistance of various materials. The equipment adopts equilibrate Conditioning Control System (BTHC), which intelligently adjusts the output power through the controller to ensure the stability of temperature and humidity in the box, and has energy-saving functions. It is suitable for electronics, electrical appliances, communications, meters, vehicles, plastic products, metals, food, chemicals, building materials, aerospace and other products for mass detection.
1. The product has beautiful appearance, reasonable structure, precise process, simple and convenient operation, stable and reliable performance. The controller uses a large color liquid crystal man-machine touch dialog LCD interface, with Chinese and English display, simple operation, and can realize remote control of RS232 computer interface. 3. The refrigeration circulation system adopts the original imported Japanese "Sanyo" brand fully enclosed Compressor (purchased from France Taikang Compressor), the parts are imported, and the refrigerant adopts American environmentally friendly refrigerant. 4. A 50mm diameter test hole is reserved on the left side of the test chamber. 5, with automatic, high precision system loop, using P.I.D automatic calculation control, the whole area temperature with High Accuracy, High Stability. 6. Specially designed air circulation circulation system and sensing system to ensure Temperature Uniformity in the box and avoid dead ends. 7. Adopt enlarged observation window, 4 layers of whole empty tempered Glass, wide field of vision. 8. The instrument has a comprehensive protection system, including power overload, leakage, control loop overload, short circuit, Compressor, grounding, over-temperature protection and alarm sound prompts, etc., and automatically displays and stops when the fault occurs.
The device adopts equilibrate Conditioning Control System (BTHC). The induction system transmits the actual temperature and humidity data in the test chamber to the controller. The controller controls the SSR (solid state relay) to perform multi-stage intelligent output, and equilibrate the output power of the temperature and humidity system to ensure that the temperature and humidity in the test chamber are fully stable. The system also has energy-saving function, which can reduce the power of the instrument to a greater extent and ensure the long-term accurate and stable operation of the instrument.
Electronics, electrical appliances, communications, instrumentation, vehicles, plastic products, metals, food, chemicals, building materials, aerospace
The data did not mention specific compliance criteria
The information does not provide specific operation steps
• The instrument has a comprehensive protection system, and any abnormal situation will automatically display the fault point and cause and stop, which needs to be dealt with in time. • Use environment requirements: The working environment temperature is recommended to be 5~ 25 ° C, and Miscellaneous items cannot be placed within 60CM of the equipment. • The humidification system has water filtration, but still needs to be paid attention to avoid blockage and maintain it regularly. • When moving the device, you can use the bottom high-bearing heavy-duty universal wheel to pay attention to smooth movement. • The shelf layer distance is adjustable and can be directly removed. Pay attention to safety during operation, and the single-layer load does not exceed 20KG. • The test hole on the left side of the equipment is used for wiring harness passing, pay attention to its parcel and protection when using it.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.