Temperature control accuracy of +/- 0.1 ℃, humidity accuracy of +/- 1% RH, using French Taikang Compressor and multi-wing air supply circulation, Temperature Uniformity ≤ +/- 2 ℃, equipped with independent temperature limit alarm and large observation window.
Category : Temperature Humidity Chamber
Brand : ZKHS
SKU : NB041013
Service :The delivery and service By NBCLab.Com
ZKHS HS-500B Constant Temperature and Humidity Chamber is a testing device used to simulate and test the performance of products in specific temperature and humidity environments. It is suitable for aviation, automotive, home appliances, scientific research and other fields to test and determine the parameters and performance of electrical, electronic and Miscellaneous products and materials under high temperature, low temperature, heat and humidity or constant test environment changes.
1. The box body is processed and formed by numerical control machine tool, which is beautiful and easy to operate. 2. The liner is made of imported stainless steel (SUS304) mirror plate argon arc welding, and the shell is sprayed with A3 steel plate. 3. Equipped with a 7.0-inch large screen, it is easy to operate and program edit. 4. Equipped with a large observation window with lighting and double-decked Glass, it is convenient to clearly observe the conditions in the box. 5. Equipped with an independent temperature limit alarm system to ensure the safe operation of the experiment. 6. Optional recorder and printer for recording parameters and printing temperature and humidity changes Linear dispersion. 7. The refrigerator adopts the original French "Taikang" fully enclosed Compressor unit. 8. The multi-wing blower is used for strong air circulation to ensure uniform temperature distribution in the test area. 9. The air passage circulates the air outlet and return air design, the wind pressure and wind speed meet the test standards, and the temperature stabilizes quickly after opening the door. 10. The heating and cooling systems are fully independent, which helps to reduce testing costs, increase lifespan, and reduce failure rates.
The equipment uses an independent heating system (nickel-chromium alloy electric heating heater), a humidification system (built-in isolated, all stainless steel shallow surface evaporative humidifier), a dehumidification system (evaporator coil dewpoint temperature laminar contact dehumidification method) and a refrigeration system (fully enclosed air-cooled compression refrigeration method) to precisely control the temperature and humidity in the box. Temperature-resistant and low-noise air-conditioning motors drive multi-blade centrifugal wind turbines for strong air supply circulation to ensure uniform and stable temperature and humidity in the box.
Aviation, automotive, home appliances, scientific research
GB/T5170.5-2008、GB/T10586-2006、GB/T2423.1-2008、GB/T2423.3-2006
1. Place the equipment in a compliant environment (5 ° C~ + 30 ° C, humidity ≤ 85% R.H), and connect the power supply to meet the specifications (AC220V +/- 10% 50Hz or AC380V +/- 10% 50Hz three-phase five-wire system). 2. Set the required temperature, humidity, test time and other parameters through the 7.0-inch large screen controller. 3. Put the sample to be tested on the test rack in the box. If you need an external connection, you can use the φ 50mm test hole on the left side of the box. 4. Start the device, and the device will run automatically according to the set program, allowing you to observe the internal situation through a large observation window. 5. After the test, the equipment stops running and the sample is taken out. 6. Optional recorder and printer can be used to record and output test data.
Equipment should be installed in the required environment temperature (5 ℃~ + 30 ℃) and humidity (≤ 85% R. H) conditions. • Power supply voltage meets equipment requirements (AC220V +/- 10% 50Hz or AC380V +/- 10% 50Hz three-phase five-wire). • The equipment is equipped with an independent temperature limit alarm system and multiple safety protections (leakage, short circuit, overtemperature, water shortage, motor overheating, Compressor overvoltage, overload, overcurrent protection), but it still needs to be checked regularly to ensure its effectiveness. • Humidified water supply is automatically controlled to ensure normal water supply. • The door opening operation may cause fluctuations in temperature and humidity in the box, please pay attention to safety and minimize the door opening time. Do not make unnecessary internal adjustments or touch high/low temperature parts while the equipment is running. • Regularly maintain and clean equipment to ensure its long-term stable operation.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.