Please contact customer service
Using French Taikang Compressor refrigeration, Temperature Uniformity ≤ +/- 2 ℃, humidity deviation + 2, -3% RH. With independent temperature limit alarm, multi-wing circulating air supply and rapid temperature stabilization functions to ensure test safety and uniformity.
Category : Temperature Humidity Chamber
Brand : ZKHS
SKU : NB041015
Service :The delivery and service By NBCLab.Com
HS-010B Constant Temperature and Humidity Chamber is a ZKHS brand environmental testing equipment. This product is suitable for aviation, automotive, home appliances, scientific research and other fields, used to test and determine the parameters and performance of electrical, electronic and Miscellaneous products and materials under high temperature, low temperature, heat and humidity or constant test temperature environment changes.
1. The box body is processed and formed by numerical control machine tool, which is beautiful and easy to operate. 2. The inner tank of the box is made of imported stainless steel (SUS304) mirror plate argon arc welding, and the shell is sprayed with A3 steel plate. 3. Adopt a 7.0-inch large-screen screen, which is easy to operate and easy to edit programs. 4. Large observation window with lighting, double-decked Glass, easy to clearly observe the situation inside the box. 5. Equipped with an independent temperature limit alarm system to ensure the safe operation of the experiment. 6. Optional recorder and printer for recording parameters and printing temperature and humidity changes Linear dispersion. 7. The refrigerator adopts the original French "Taikang" fully enclosed Compressor unit. 8. The use of a multi-wing blower for strong air circulation allows for uniform temperature distribution in the test area. 9. The air passage circulates the air outlet and return air design, the wind pressure and wind speed meet the test standards, and the temperature stabilizes quickly after opening the door. 10. Heating, cooling, and complete system independence can effectively reduce testing costs, increase lifespan, and reduce failure rates.
The Constant Temperature and Humidity Chamber precisely controls the temperature and humidity environment in the box through an independent heating system, humidification system, refrigeration system and circulation system. The heating system adopts a nickel-chromium alloy electric heating heater; the humidification system adopts a built-in isolated, all stainless steel shallow surface evaporative humidifier, which is controlled by an automatic water supply system; the dehumidification system adopts an evaporator coil dewpoint temperature laminar contact dehumidification method; the refrigeration system adopts a fully enclosed air-cooled compression refrigeration method, and the core is the French "Taikang" unit; the circulation system realizes strong air supply circulation through a temperature-resistant and low-noise air-conditioning motor and a multi-leaf centrifugal wind turbine to ensure uniform and stable temperature and humidity.
Aviation, automotive, home appliances, scientific research
GB/T5170.5-2008、GB/T10586-2006、GB/T2423.1-2008、GB/T2423.3-2006
1. Place the equipment in a compliant environment (temperature 5 ° C~ + 30 ° C, humidity ≤ 85% R.H), and connect the power supply to meet the specifications (AC220V +/- 10% 50Hz or AC380V +/- 10% 50Hz three-phase five-wire system). 2. Connect the sample line to be tested (if necessary) through the φ 50mm test hole on the left side of the box. 3. Turn on the power supply of the device and use the 7.0-inch large screen controller to set the required temperature, humidity, test time and other parameters. 4. Place the sample to be tested on the test rack in the box and close the box door. 5. Start the test program, the device will run automatically, and the internal condition can be monitored through the observation window. 6. After the test is completed, the equipment stops running and the sample is removed. 7. If you need to record data, you can obtain setting parameters and temperature and humidity changes through the optional recorder and printer. Linear dispersion.
Equipment should be installed in the required environment temperature (5 ℃~ + 30 ℃) and humidity (≤ 85% R. H) conditions. • Power supply voltage must meet equipment requirements (AC220V +/- 10% 50Hz or AC380V +/- 10% 50Hz three-phase five-wire). The equipment is equipped with an independent temperature limit alarm system, which will automatically interrupt if the temperature exceeds the limit, but it is still necessary to regularly check whether the safety protection function is normal. • The equipment has multiple safety protections such as leakage, short circuit, over temperature, water shortage, motor overheating, Compressor overvoltage, overload, overcurrent, etc., but safety still needs to be paid attention to during operation. • The humidified water supply is automatically controlled to ensure that the water source is normal. After the door opening operation, due to the wind circuit design, the temperature recovery time is faster, but the door opening time and frequency should still be minimized to maintain the stability of the test conditions. • Optional recorder and printer are extra functions, not included in standard configuration, please select separately if necessary.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.