$ 18437.00Ex works
Temperature range -55 ° C to + 150 ° C, Impact conversion time ≤ 10 seconds, equipped with 120 sets of program capacity and USB data storage function, using environmentally friendly refrigerant R404A/R23 to ensure test Stability and data traceability.
Category : Thermal Shock Test Chamber
Brand : HUDA
SKU : NB041400
Service :The delivery and service By NBCLab.Com
HUDA QD-E703-150K55 Thermal Shock Test Chamber is a testing equipment required by the metal, plastic, rubber, electronics and other material industries. It uses the method of immobility of the item to be tested to test the impact of rapid changes in high and low temperatures on the product. All functions of the device are computer-controlled, equipped with self-developed software, and have a good operation interface. It supports program maintenance, temporary parameter modification and automatic cooling and heating switching functions.
1. Adopt imported LED digital display microcomputer integrated controller, touch input is easy to operate 2. Large program capacity, supports up to 120 sets of programs, and can be connected and used between programs 3. With USB storage function, it can backup parameters, programs and operation Linear dispersion records 4. Equipped with RS-232/RS-485 communication interface, support remote monitoring and data collection 5. Using environmentally friendly refrigerant R404A/R23 6. Key components adopt internationally renowned brands, such as France Taikang Compressor, Denmark Danfoss expansion valve, etc 7. With multiple safety protection devices, including Compressor overheating protection, over-temperature protection, leakage protection, etc 8. Support Chinese and English language switching, with reservation start and power-off memory functions
Through the built-in high temperature zone and low temperature zone air valve, loop air duct and stainless steel loop fan, the test product is sent to the heat and cooling capacity space by switching the basket to achieve rapid temperature alternation. Instantly introduce the basket into the low temperature test chamber during low temperature Impact, and instantly introduce the basket into the high-temperature test chamber during high temperature Impact, so as to achieve the purpose of Thermal Shock test.
Electronic products, automotive parts, high-tech products, metal materials, plastic materials, rubber materials
MIL STD, GB, JIS, JEDEC, IEC, GB/T 2423.1 - 1989 Low Temperature Test Method, GB/T 2423.2 - 1989 High Temperature Test Method, GB/T 2423.22 - 1989 Temperature Change Test, GJB150.5-86 Temperature Impact Test, GJB360.7-87 Temperature Impact Test, GJB367.2-87 405 Temperature Impact Test, Japanese Industrial Standard JIS, Industrial Standard JESD22, Communication Industry Standard GR-1221-CORE, GB T 10589-2008 Low Temperature Test Chamber Technical Conditions, GB T 11158-2008 High-temperature test chamber Technical Conditions
1. Set the time and parameters through the touchscreen Select or edit test programs (up to 120 groups) 3. Set the number of program executions (up to 9999 times per command) 4. Start the program to run and monitor Linear dispersion and data in real time 5. Export data via USB after the test is completed 6. Use the supporting software to analyze the test data
Equipment environment temperature should be kept within 0 ℃~ +/- 35 ℃, relative humidity ≤ 85% When the environment temperature is lower than 0 ℃, the water left in the equipment should be drained clean • The distance between the left and right sides of the test chamber and the rear side panels shall not be less than 500mm, and the front distance shall not be less than 1000mm • Before installation, confirm whether the equipment location, size and channel meet the requirements • Power supply voltage is 380V with 3 phases and 5 wires, and it is necessary to ensure that the voltage fluctuation range is within 10% • Pay attention to observe the status of various protective devices when the equipment is running • Regularly check the operation status of the refrigeration system and heating system
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.