The binary duplex refrigeration system is used to achieve -60 ° C low temperature control, equipped with 120 sets of program capacity and 7.5-inch true color touch screen, with PID automatic calculation and network remote monitoring functions, and supports 600kg/m2 uniform load.
Category : Temperature Humidity Chamber
Brand : HUDA
SKU : NB041454
Service :The delivery and service By NBCLab.Com
HUDA QD-E705-12m ³ (-60 ℃) humidity chamber is a walk-in test equipment, suitable for industrial products humidity cabinet test, high temperature test, low temperature test and high and low temperature gradual change test. The equipment has a wide limit Temperature range (-60~ 80 ℃), high actual temperature and humidity accuracy. Inner chamber dimensions can be customized, suitable for temperature and humidity testing of various components and complete machines.
1. High Strength and Reliability Structure Design Ensure High Reliability of Equipment 2. Large window design for easy observation of indoor specimen condition 3. High wind speed, uniform sample exposure, effectively ensure the uniformity of the test room 4. Unique door lock design using lever principle, good sealing, with anti-lock function 5. The warehouse structure has high seismic resistance, good corrosion resistance, and convenient installation and disassembly construction 6. The inner box is made of SUS304 stainless steel plate, the outer box is made of plastic-sprayed galvanized color steel plate, and the middle is filled with temperature-resistant stress insulation material 7. Heating system, refrigeration system, electrical system has been modular and separate layout, better safety performance 8.7.5 True color display screen, support Chinese and English language conversion 9. Large program capacity, up to 120 sets of programs, repeability, execution of commands up to 999 times each 10. With network connection function, support remote control and data collection
The test chamber realizes temperature and humidity control through the cooperative work of heating system, refrigeration system and humidification and dehumidification system. The refrigeration system adopts a set of binary duplex refrigeration system, including high temperature stage and low temperature stage refrigeration cycle, and the heat exchange is realized through evaporative condenser. The humidification system adopts external humidification mode. The special dehumidification Compressor starts the dehumidification, and the humidification amount is controlled by P.I.D. to reach the required humidity. All system operation programs are completely controlled by the microcomputer controller to ensure a precise and stable temperature and humidity environment.
Aerospace Industry, PCB Substrate, Electronic Chip IC, Semiconductor Pottery and porcelain, Polymer Materials, Electronics Components, Metals, Chemical Materials, Automation Components, Communication Components, National Defense Industry
GB2423.1-2008/IEC6008-2-1-2007、GB/T 2423.2-2008、GJB150.3A-2009、GJB150.4A-2009、GB/T 10589-2008、GB/T2423.3-2008(IEC68-2-3)、GJB150.9A-2009、G/BT 2423.4-2008/IEC6008-2-30:2005、GB/T5170.18-2005、GB/T10586-2006
1. Turn on the power supply and turn on the main power switch 2. Set test parameters (temperature, humidity, time, etc.) through the touch screen. 3. Select the operation mode (program mode or set value mode) 4. Start the equipment and start the test 5. Monitor the test process through the observation window 6. Equipment stops automatically or manually after the test is completed 7. Remove the specimen and turn off the power
• Prohibition of testing of flammable, explosive and volatile matter samples • Tests prohibiting the storage of samples of corrosive substances Prohibition of storage of organisms for testing • Tests prohibiting the storage of samples of strong electromagnetic emission sources • Require users to configure air or power switches of corresponding capacity at the installation site • The grounding resistance of the protective ground wire should be less than 4Ω. • The working environment temperature should be within the range of 5 ° C~ + 35 ° C • Working environment humidity should be ≤ 85% • Humidification water requires tap water and three-stage Filter • The water supply pressure should be within the range of 0.1 to 0.4MPa
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.