$ 10256.00Ex works
Temperature range of -70~ 150 ℃, humidity control range of 20~ 98% RH. With 1000 program control, automatic calculation function and 15 safety detection, support RS-232 communication interface and Chinese and English display switching.
Category : Temperature Humidity Chamber
Brand : kesionots
SKU : NB041484
Service :The delivery and service By NBCLab.Com
KESIONOTS KS-HW1000L (150 ℃) humidity chamber is a device that can accurately simulate complex natural environments such as low temperature, high temperature, high temperature and humidity, low temperature and low humidity. It is suitable for product Reliability testing in plastics, electronics, food, clothing, vehicles, metals, chemicals, building materials and other industries. The equipment adopts advanced refrigeration, heating and temperature and humidity control systems to ensure the Stability and accuracy of the test environment.
1. With the function of automatic calculation 2. With fixed temperature and slope setting function 3. With hold, skip, standby and two sets of time signal output functions 4. With cold/heat engine start-up selection function 5. With temperature display value correction function 6. With temperature sensor calibration function 7. With Compressor automatic stop function 8. With reservation start/stop function 9. With power failure memory function: when the power is cut off, the program data memory can be maintained for 6 months 10. Powerful network monitoring and control capabilities 11. With a capacity of 1000 programs, each segment can cycle 999 steps, and the MAX Maximum is set to 99 hours and 59 minutes per segment 12. With fault alarm and cause, processing prompt function 13. With upper and lower limit temperature protection function 14. With self-diagnostic function 15. With PC link function
The refrigeration system of the humidity chamber adopts cascade refrigeration, which consists of high temperature part and low temperature part. It is connected by evaporative condenser to realize low temperature refrigeration. The heating system consists of high power resistance wire to ensure rapid heating up. The temperature and humidity system includes humidification and dehumidification subsystem. The humidification adopts steam humidification method, and the dehumidification adopts mechanical refrigeration dehumidification or drying dehumidification method. The Sensor system uses platinum resistance and Thermocouple for temperature measurement, and the solid state electronic Sensor for humidity measurement.
Plastics, electronics, food, clothing, vehicles, metals, chemicals, building materials
GB5170、2、3、5、6-95、GB2423.1-89 (IEC68-2-1)、GB2423.2-89 (IEC68-2-2)、GB/T2423.3-93(IEC68-2-3)、GB/T423.4-93(IEC68-2-30)、GJB150.3(ML-STD0-810D)、GJB150.4(MIL-STD-810D)、GJB150.9-1986、GJB4.6-1983、GJB367.2-1987、GJB4.5-1983、GB10592-93、GB10586-93、GJB360.8-87(MIL-STD-202f)、GB/T5170.2-96、GB/T5170.5-96、YD1268-2003、UL1642、UN38.3、GB/T18287-2000、GB8897.4-2002、UL2054-2005、SJ/T 11169-1998、GB8897.4-2002、SJ/T11170-1998、YD1268.2-2003、QC/T743-2006、QC/T744-2006
1. Set the test program: use the programmable controller to set the temperature, humidity and other parameters 2. Start the device: Select the cold or hot engine start mode 3. Monitoring operation: Linear dispersion and data are observed through the display screen 4. Handling abnormalities: In case of failure, the system will automatically alarm and prompt the handling method 5. Complete the test: the device automatically stops or manually ends operation
• Power supply voltage must be 220V AC (+/- 10%), protective grounding resistance ≤ 4Ω • Do not use knife switches or power sockets, use air switches (40A) • The resistivity of humidification water needs to be ≥ 500MΩ • The weight of the product rack does not exceed 20 kg Equipment with air burn prevention, high voltage protection, overheating protection, overcurrent protection and other safety devices • The start-stop function can be locked during operation to prevent accidental touch from affecting the experimental results
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.