$ 5523.00Ex works
Adopt cascade refrigeration system, Temperature range -40~ 150 ℃, humidity control range 20~ 98% RH, with 1000 segment program capacity and 15 safety detection functions, support remote monitoring.
Category : Temperature Humidity Chamber
Brand : kesionots
SKU : NB041505
Service :The delivery and service By NBCLab.Com
KESIONOTS KS-HW150D (150 ℃) humidity chamber is a device that can accurately simulate complex natural environments such as low temperature, high temperature, high temperature and high humidity, low temperature and low humidity. It is suitable for product Reliability testing in plastics, electronics, food, clothing, vehicles, metals, chemicals, building materials and other industries.
1. With the function of automatic calculation 2. With fixed temperature and slope setting function 3. With hold, skip, standby and two sets of time signal output functions 4. With cold/heat engine start-up selection function 5. With temperature display value correction function 6. With temperature sensor calibration function 7. With Compressor automatic stop function 8. With reservation start/stop function 9. With power failure memory function: when the power is cut off, the program data memory can be maintained for 6 months 10. Powerful network monitoring and control capabilities 11. With a capacity of 1000 programs, each segment can cycle 999 steps, and the MAX Maximum is set to 99 hours and 59 minutes per segment 12. With fault alarm and cause, processing prompt function 13. With upper and lower limit temperature protection function 14. With self-diagnostic function 15. With PC link function
The humidity chamber adopts a cascade refrigeration system, which consists of a high-temperature part and a low-temperature part. It is connected by an evaporative condenser to realize the heat exchange of the refrigerant. The heating system is composed of high-power resistance wire to ensure rapid heating. The temperature and humidity system includes steam humidification method and mechanical refrigeration dehumidification or drying dehumidification. The temperature and humidity are precisely monitored and controlled by the Sensor system.
Plastics, electronics, food, clothing, vehicles, metals, chemicals, building materials
GB5170、2、3、5、6-95、GB2423.1-89 (IEC68-2-1)、GB2423.2-89 (IEC68-2-2)、GB/T2423.3-93(IEC68-2-3)、GB/T423.4-93(IEC68-2-30)、GJB150.3(ML-STD0-810D)、GJB150.4(MIL-STD-810D)、GJB150.9-1986、GJB4.6-1983、GJB367.2-1987、GJB4.5-1983、GB10592-93、GB10586-93、GJB360.8-87(MIL-STD-202f)、GB/T5170.2-96、GB/T5170.5-96、YD1268-2003、UL1642、UN38.3、GB/T18287-2000、GB8897.4-2002、UL2054-2005、SJ/T 11169-1998、SJ/T11170-1998、YD1268.2-2003、QC/T743-2006、QC/T744-2006
1. Set the reservation start function and plan the test conditions 2. Use smart microcomputer PID + SSR/SCR Control mode for data setting and Linear dispersion rendering 3. Perform start/stop operations through the timing control interface 4. Operation lock function to prevent accidental touch 5. Select the restart mode (interrupt, cold engine start or heat engine start) when the power failure returns. 6. The safety detection device monitors the operating status and automatically cuts off the power when abnormal 7. External protection devices ensure over-temperature safety 8. Online control with PC via RS-232 interface 9. Chinese/English display switching 10. Manually add 20L of water each time to ensure the normal operation of the humidification system
• The weight of the product rack shall not exceed 20 kg • The resistivity of humidification water needs to be ≥ 500MΩ • The power switch must use an air switch (40A), and it is forbidden to use a knife switch or a power socket • Note that safety devices include air burn prevention, high voltage protection, overheating protection, overcurrent protection, Pottery and porcelain E-16 fast fuse, no fuse overload protection • The program data can be maintained for 6 months after a power outage, but attention should be paid to the selection of the restart mode • Check Sensor system before use to ensure accurate temperature and humidity measurement • Regularly maintain refrigeration and heating systems to prevent malfunctions
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
