$ 5841.00Ex works
Temperature range -40~ 150 ℃, humidity control range 20~ 98% RH, Temperature Fluctuation +/- 0.5 ℃, with automatic calculation and 1000-segment program control function, support PC link and reservation start, to ensure accurate and efficient testing.
Category : Temperature Humidity Chamber
Brand : kesionots
SKU : NB041506
Service :The delivery and service By NBCLab.Com
KESIONOTS KS-HW225D (150 ℃) humidity chamber is a device that can accurately simulate complex natural environments such as low temperature, high temperature, high temperature and high humidity, low temperature and low humidity. It is suitable for product Reliability testing in plastics, electronics, food, clothing, vehicles, metals, chemicals, building materials and other industries. The equipment adopts advanced refrigeration, heating and temperature and humidity control systems to ensure Stability and accuracy of test conditions.
1. With automatic calculation function 2. With fixed temperature and slope setting function 3. With hold, skip, standby and two sets of time signal output functions 4. With cold/heat engine start-up selection function 5. With temperature display value correction function 6. With temperature sensor calibration function 7. With Compressor automatic stop function 8. With reservation start/stop function 9. With power failure memory function, the program data memory can be maintained for 6 months after power failure 10. Powerful network monitoring and control capabilities 11. With 1000 segments, each segment can cycle 999 steps, and each segment sets the MAX Maximum to 99 hours and 59 minutes 12. With fault alarm and cause, processing prompt function 13. With upper and lower limit temperature protection function 14. With self-diagnostic function 15. With PC link function
Humidity chamber works together through the refrigeration system, heating system and temperature and humidity system to achieve accurate environment simulation. The refrigeration system adopts cascade refrigeration, which consists of two parts of high temperature and low temperature. It is connected by evaporative condenser to absorb heat separately to obtain cold capacity. The heating system is composed of high power resistance wire, which provides rapid heating capacity. The temperature and humidity system includes humidification and dehumidification subsystem. The humidification adopts steam humidification method. The dehumidification adopts mechanical refrigeration dehumidification or drying dehumidification method to ensure the sensitivity and accuracy of temperature and humidity control.
Plastics, electronics, food, clothing, vehicles, metals, chemicals, building materials
GB5170、2、3、5、6-95、GB2423.1-89 (IEC68-2-1)、GB2423.2-89 (IEC68-2-2)、GB/T2423.3-93(IEC68-2-3)、GB/T423.4-93(IEC68-2-30)、GJB150.3(ML-STD0-810D)、GJB150.4(MIL-STD-810D)、GJB150.9-1986、GJB4.6-1983、GJB367.2-1987、GJB4.5-1983、GB10592-93、GB10586-93、GJB360.8-87(MIL-STD-202f)、GB/T5170.2-96、GB/T5170.5-96、YD1268-2003、UL1642、UN38.3、GB/T18287-2000、GB8897.4-2002、UL2054-2005、SJ/T 11169-1998、SJ/T11170-1998、YD1268.2-2003、QC/T743-2006、QC/T744-2006
1. Set the test program: use the programmable controller to set parameters such as temperature, humidity, and time 2. Start the device: Select the cold or hot engine start mode and start running 3. Monitoring operation: real-time observation of temperature and humidity Linear dispersion and status through LCD display 4. Handling abnormalities: If there is a fault alarm, deal with it accordingly according to the prompts 5. End the test: automatically stop or manually stop running after the program is completed
• Power supply voltage must be 220V AC (+/- 10%), protective grounding resistance ≤ 4Ω • The resistivity of humidification water needs to be ≥ 500MΩ • The weight of the product rack does not exceed 20 kg • Use air switch (40A), prohibit the use of knife switch or power socket • Regularly check safety devices, including air burn prevention, high voltage protection, overheating protection, etc • Avoid running the equipment for a long time under abnormal conditions
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.