$ 5491.00Ex works
The cascade refrigeration system is used to achieve a low temperature of -60 ° C, equipped with a 1000-segment program control capacity, with automatic calculation and fault self-diagnosis functions, and supports RS-232 communication interface to realize multi-machine control.
Category : Temperature Humidity Chamber
Brand : kesionots
SKU : NB041521
Service :The delivery and service By NBCLab.Com
KESIONOTS KS-HW1000F (150 ℃) humidity chamber is a testing equipment that can accurately simulate complex natural environments such as low temperature, high temperature, high temperature and high humidity, low temperature and low humidity. It is suitable for product Reliability testing in plastics, electronics, food, clothing, vehicles, metals, chemicals, building materials and other industries.
1. With automatic calculation function 2. With fixed temperature and slope setting function 3. With hold, skip, standby and two sets of time signal output functions 4. With cold/heat engine start-up selection function 5. With temperature display value correction function 6. With temperature sensor calibration function 7. With Compressor automatic stop function 8. With reservation start/stop function 9. With power failure memory function: program data memory can be maintained for 6 months after power failure 10. Powerful network monitoring and control capabilities 11. With a capacity of 1000 programs, each of which can cycle through 999 steps 12. With fault alarm and cause, processing prompt function 13. With upper and lower limit temperature protection function 14. With self-diagnostic function 15. With PC link function
The refrigeration system adopts cascade refrigeration, which is composed of high temperature part and low temperature part. It is connected by evaporation condenser. The high temperature part of the refrigerant evaporates and absorbs the low temperature part of the heat. The low temperature part of the refrigerant evaporates and absorbs heat from the air in the test chamber to obtain cold energy. The heating system is composed of high-power resistance wire to achieve rapid heating. The temperature and humidity system is divided into humidification and dehumidification subsystems. The humidification adopts steam humidification method, and the dehumidification adopts two ways of mechanical refrigeration dehumidification and drying dehumidification. The Sensor system uses platinum resistance and Thermocouple measurement temperature, and the solid
Plastics, electronics, food, clothing, vehicles, metals, chemicals, building materials
GB5170、2、3、5、6-95、GB2423.1-89 (IEC68-2-1)、GB2423.2-89 (IEC68-2-2)、GB/T2423.3-93(IEC68-2-3)、GB/T423.4-93(IEC68-2-30)、GJB150.3(ML-STD0-810D)、GJB150.4(MIL-STD-810D)、GJB150.9-1986、GJB4.6-1983、GJB367.2-1987、GJB4.5-1983、GB10592-93、GB10586-93、GJB360.8-87(MIL-STD-202f)、GB/T5170.2-96、GB/T5170.5-96、YD1268-2003、UL1642、UN38.3、GB/T18287-2000、GB8897.4-2002、UL2054-2005、SJ/T 11169-1998、GB8897.4-2002、SJ/T11170-1998、YD1268.2-2003、QC/T743-2006、QC/T744-2006
1. Set up program catalog management, establish test names and program data 2. Select the operation mode: fixed value/program/link 3. Set the reservation start function 4. Lock the start and stop function conditions 5. Configure the humidification system to add water manually 6. Place the product on the test rack (load-bearing within 20 kg) 7. Start the operation program
• Power supply voltage must be 220V AC (+/- 10%), protective grounding resistance ≤ 4Ω • The resistivity of humidification water needs to be ≥ 500MΩ • The load-bearing capacity of the product rack does not exceed 20kg • Do not use knife switch or power socket, use air switch (40A) • Note that safety devices include air burn prevention, high voltage protection, overheating protection, overcurrent protection, etc • Pay attention to the locking function when operating to prevent accidental touch
I recommend this constant temperature and humidity test chamber. It covers a temperature range from -60℃ to 150℃, meeting the requirements for high-temperature testing of lithium batteries. The humidity control range is 20% to 98% RH, with good precision. It supports complex program settings and cyclic testing, making it suitable for simulating the performance changes of lithium batteries under different temperature and humidity conditions, ensuring the accuracy and reliability of the tests.
If constant value testing is the main focus, we recommend paying attention to the control stability and ease of use of the equipment. The intelligent PID control of this test chamber ensures that temperature and humidity remain stable at the set values for extended periods. It features a large color touchscreen with a user-friendly interface that supports both Chinese and English, making parameter settings intuitive. Despite its many functions, the constant value mode is straightforward to operate. Additionally, it comes with a built-in RS-232 communication interface, allowing easy connection to a computer for remote monitoring and data recording, which greatly simplifies data management and analysis in later stages.