Humidity light is precisely controlled by microcomputer, and 30 programs can be set to simulate day and night changes. Equipped with energy-saving LED Illuminant, volume 250 liters, mirror stainless steel liner for easy cleaning, with independent temperature limit alarm function.
Category : Incubator
Brand : sanfa
SKU : NB041703
Service :The delivery and service By NBCLab.Com
GMP-250 light chamber is an intelligent microcomputer-controlled constant temperature and humidity light experimental equipment, using mirror stainless steel liner with a volume of 250L. It is widely used in microbial tissue cell fostering, seed germination, seedling test, plant cultivation, and insect and small animal feeding. It can accurately simulate different environment climate conditions and is an ideal device for R & D institutions to engage in production and scientific research.
1. Using microcomputer to control temperature and Humidity, the control is stable and accurate. 2. Humanized touch buttons, large-screen LCD display, intelligent program control temperature, Humidity, lighting, menu operation, multiple parameters are displayed on the same screen. 3. Mirror stainless steel liner, four corners and half arc design, easy to disinfect and clean the studio, Shelf can be adjusted arbitrarily. 4. 30-segment program can be set to simulate the temperature, Humidity, and light changes of nature during the day and night, and can also simulate the multi-directional Illuminant of nature. There is a function of automatically storing set parameters in the event of a power outage. 5. Equipped with a variety of LED Illuminants suitable for plant growth, no thermal interference, energy saving and environmental protection, stability, long life, high photoelectric conversion efficiency, and extraction of useful light conducive to plant growth. Optional overhead flat light. 6. A suitable air duct circulation system ensures that the wind inside the studio is evenly distributed and does not blow to plant seedlings. 7. Key components such as Compressors and circulating fans are brand products, which are safe and reliable. 8. Independent temperature limit alarm system, which automatically interrupts when the temperature exceeds the limit to ensure the safe operation of the experiment without accidents (optional). 9. The upgraded new light chamber (E series) also has a large-screen color screen display, multiple sets of data are displayed on one screen, and the Illumrination degree is automatically detected and controlled by the Light Sensor to reduce the attenuation and error caused by the aging of the lamp tube. SMS alarm system (optional), which can send fault information in time through SMS. 10. Upgraded intelligent programmable lighting chamber, with a large screen LCD controller, more innovative appearance, temperature control, Illumrination degree more accurate, more perfect protection, and can be equipped with RS-485 interface, can be connected to printers and computers, record temperature changes (optional).
The light chamber precisely controls the internal temperature, Humidity and lighting conditions through an intelligent microcomputer Control system. The system can be programmed to set up to 30 different environment parameters (Temperature, Humidity, Light) to simulate day and night changes and multi-directional Illuminants. Equipped with an air duct circulation system to ensure a uniform and stable environment in the box, LED Illuminant provides specific Light spectrum to promote plant growth, and key components such as Compressors and circulating fans ensure long-term reliable operation of the equipment.
Microbial tissue cell foster, seed germination, seedling test, plant cultivation, insects, small animal breeding, colleges, laboratories, environment protection, agriculture, forestry and animal husbandry R & D institutions
fluorine free
1. Turn on the power supply (220V 50Hz). 2. Perform menu operation through touch buttons and large-screen LCD to set the required temperature, Humidity, Illumrination degree and program segment parameters. 3. You can choose the lighting method (such as two-sided lighting, three-sided lighting, Shelf-type lighting) and the lighting level (general light 0~ 6000LX five-level adjustable or strong light 0~ 20000LX percentage adjustable). 4. Set the program (up to 30 segments), each segment can be set to run time (1-9999 minutes) to simulate changes in the natural environment. 5. Start the device, and the microcomputer will automatically control the program that runs the settings. 6. After the experiment, turn off the device and disconnect the power supply.
The Ambient Temperature should be between 5 and 35 ℃. When the device is running, do not open and close the door frequently, so as not to affect the internal environment Stability. Regularly clean and disinfect the stainless steel liner to maintain hygiene. Do not block the entry and exit trend to ensure that the air duct circulation system works normally. If an independent temperature limiting alarm system is selected, it is necessary to ensure its normal function to ensure the safety of the experiment. Before performing equipment maintenance or cleaning, be sure to disconnect the power supply. Optional SMS alarm or RS-485 interface and other functions need to be installed and set up according to the relevant instructions.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.