Please contact customer service
With IP65 Protection Rating, support PH, ORP and temperature Multi-ParaMeter simultaneous measurement, Measurement accuracy of +/- 0.02pH, Stability ≤ 0.01pH/24h, with automatic temperature compensation, RS-485 Communication interface and 4-20mA current output function, suitable for complex industrial environments.
Category : Water Quality Tester
Brand : NOBOTECH
SKU : NB041733
Service :The delivery and service By NBCLab.Com
PH-1186 is a new generation of intelligent industrial online pH meter independently developed by NOBOTECH brand. It has the characteristics of Chinese menu operation, high Stability and excellent repeability. It can accurately measure the pH value, Oxidation-reduction potential (ORP) and temperature value in the solution. It is widely used in wastewater treatment, purified water, circulating water, boiler water and other systems as well as PH/ORP value online detection in electronics, breeding, food, printing and dyeing, Eletroplating, fermentation, chemical industry and other process fields. Powerful in environment monitoring and remote system applications such as surface water and pollution source discharge.
1. Adopt new waterproof, dustproof and moisture-proof good shell (IP65) process, surface painting, Appearance generous high-end. 2. The product has High Accuracy, High Stability and Strong Anti-interference. 3. Large screen point matrix LCD display, support Chinese and English menu switching, can display PH/ORP value, temperature, output current, alarm point and other Multi-Parameters at the same time. 4. With automatic temperature compensation function, you can manually correct the pH and temperature value. 5. Powerful communication function, using interface photoelectric isolation technology, with RS-485 Communication interface (optional, MODBUS protocol partially compatible), can convert RS-232. 4-20mA current output corresponding to the PH value can be arbitrarily set and support positive and negative control. 6. Support the company's internal Internet of Things and customer-customized Internet of Things, with optional host computer online acquisition software. 7. With notepad function, PH/ORP mode can store 50 measurement data respectively. 8. Automatically identify the standard solution and restore the factory settings. 9. Equipped with watchdog function to ensure that the meter does not crash. 10. Power failure protection time is greater than 10 years. 11. Core components are sourced from foreign brands.
The PH-1186 industrial online pH meter obtains the pH value through the Sensor measurement of hydrogen ion concentration in the solution, and can also measure Oxidation-reduction potential (ORP) and temperature. The meter adopts a high input Impedance design (≥ 1 × 10 ^ 12Ω) to ensure the Stability of the measurement signal. The temperature correction of the PH Measured value is carried out through the automatic temperature compensation function to improve the measurement accuracy. The measurement data can be displayed on a large screen LCD, and can be transmitted and controlled remotely through the 4-20mA current signal or the RS-485 Communication interface.
Wastewater treatment, pure water, circulating water, boiler water and other systems, electronics, breeding, food, printing and dyeing, Eletroplating, fermentation, chemical industry and other process fields, surface water and pollution source discharge and other environment monitoring and remote system applications
MODBUS protocol partially compatible
1. Install the instrument and ensure that the opening size of the disk is 92 x 92mm. 2. Connect the power supply (220VAC or book DC24V/DC12V power supply) and Sensor. 3. After booting, use the Chinese menu to set the parameters. 4. Use standard solution (such as 6.86/4 00/9.18 or 7.00/4 00/10.01) for pH correction, the correction range is zero +/- 1.45PH, slope +/- 30%. 5. Set the temperature compensation range (0-99.9 ℃), alarm control point (high/low point), 4-20mA output range and relay lag as needed. 6. The instrument can automatically identify the standard liquid and start the online measurement of PH, ORP and temperature values. 7. The measurement data can be displayed in real time and can be stored through the notepad function (up to 50 items). 8. Connect the host computer or Control system through RS-485 interface (optional) or 4-20mA output to realize data collection and remote monitoring.
* Ambient Temperature between 0~ 60 ℃, relative humidity ≤ 90%. * 4-20mA current output load should be less than 750Ω. * Relay load is 3A-220VAC, do not overload when using. * Instrument Protection Rating is IP65, but the installation still needs to be careful to avoid long-term exposure to extreme humidity or dust environment. * When pH calibrating, use the specified standard buffer to ensure Measurement accuracy. Although the core components are from foreign brands, they still need regular maintenance and calibrating to ensure performance. * RS-485 communication function is optional, please confirm the booking model if you need to use it. * The meter supports factory reset. Please confirm that important data has been backed up before operation.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.