Overview
LICHEN single channel adjustable micro Pipette (model: 20-200 μl) is a small volume pipetting tool commonly used in biological and chemical laboratories. The product is ergonomic, comfortable to the touch, light to operate, helps to avoid muscle strain injury of Repeatability, and has a long service life. It is suitable for laboratories in many scientific fields such as clinical diagnosis, biotechnology, pharmacy, chemistry, environment and food.
Features
1. The pipette rod can be swirled/spun at 360 ° and can be disassembled for high temperature sterilization at 121 ° C.
2. Ergonomic design for long service life.
3. Comfortable to the touch, light suction and drainage operation, helps to avoid Repeatability muscle strain.
4. With high accuracy, low error coefficient, more accurate liquid removal.
5. Pipette has a long service life and low maintenance costs.
Principle
The product is a single-channel adjustable micro-Pipette. Through the reciprocating motion of the piston, a negative or positive pressure is formed in the suction head, so as to achieve accurate absorption and discharge of liquid. Users can set the desired pipette volume by adjusting the range knob.
Applications
Clinical diagnostic laboratories, biotechnology laboratories, pharmacy and chemistry laboratories, environment laboratories, food laboratories
Steps
1. According to the required volume, adjust the swirl/spin range knob to the target value.
2. Put the matching tip vertically on the front end of the Pipette and ensure sealing.
3. Hold the Pipette vertically and immerse the tip of the tip below the liquid level.
4. Release the operation button slowly and smoothly to absorb the liquid.
5. Move the suction head to the target container, slowly and smoothly press the operation button to the first stop point to discharge the liquid, and continue to press to the second stop point if necessary.
6. Press the back suction head button to remove the used suction head.
Notice
• Please calibrate according to the operating instructions before use.
• Select tips that match Pipette's range and liquid properties.
• When absorbing the liquid, keep the Pipette vertical and the tip is immersed in the appropriate depth.
• When draining, the tip of the suction head should contact the inner wall of the container, and the action should be slow and smooth.
• Pipettes and suction heads are precision devices and should be handled with care to avoid violent collisions.
• Periodic maintenance and performance checks of Pipette.
• Do not use Pipette to remove highly volatile, corrosive or radioactive liquids.
• The high temperature sterilizing part is limited to the removable pipette rod, please do not sterilize the whole at high temperature.