Overview
LICHEN single channel adjustable micro Pipette (model: 100-1000 μl) is a small volume liquid removal tool commonly used in biological and chemical laboratories. The Pipette is ergonomic, comfortable to the touch, light to operate, helps to avoid muscle strain Repeatability, and has a long service life and low maintenance cost. It is suitable for laboratories in the scientific fields of clinical diagnosis, biotechnology, pharmacy, chemistry, environment and food.
Features
1. Pipette rod can be swirled/spun 360 degrees, and can be removed for high temperature sterilization at 121 ° C.
2. Ergonomic design for long service life.
3. Comfortable to the touch, light suction and drainage operation, helps to avoid Repeatability muscle strain.
4. With high accuracy, low error coefficient, more accurate liquid removal.
5. Pipette has a long service life and low maintenance costs.
Principle
The micro-Pipette creates negative or positive pressure in the tip through the reciprocating motion of the piston, thus achieving precise liquid absorption and drainage. Its adjustable design allows the user to set the required pipette volume according to the range (100-1000 μl).
Applications
Clinical diagnostic laboratories, biotechnology laboratories, pharmacy and chemistry laboratories, environment laboratories, food laboratories
Steps
1. Adjust the swirl/spin knob to set the volume according to the required pipetting volume.
2. Install the appropriate suction head vertically on the front end of the Pipette.
3. Hold the Pipette vertically and immerse the tip of the tip below the liquid level.
4. Release the operation button slowly and smoothly to absorb the liquid.
5. Move the suction head to the target container, press the operation button smoothly to the first stop point to discharge the liquid, and continue to press to the second stop point to blow out the residual liquid.
6. Press the back suction head button to remove the used suction head.
Notice
When setting the volume, do not exceed the range (100-1000 μl).
• When installing the suction head, please ensure that it is tight to avoid air leakage affecting the accuracy.
• When absorbing liquid, it should be operated slowly and smoothly to avoid the liquid rushing into the interior of the Pipette.
• Pipette and suction head should be used together, it is recommended to use original or recommended brand suction head.
• After use, adjust the Pipette range to MAX Maximum to maintain internal spring resilience.
• Pipette is regularly calibrated and maintained to ensure accuracy.
• For high temperature sterilization, autoclaving only the removable pipette rod portion at 121 ° C.