Please contact customer service
Using French imported Compressor and environmental refrigerant R404A, temperature control accuracy of +/- 0.1 ℃, humidity accuracy of +/- 1% RH. Equipped with 7-inch touch screen, support 100 sets of programs and 5000 segments editing, with power-off memory and Linear dispersion display function.
Category : Temperature Humidity Chamber
Brand : JiangKai
SKU : NB042188
Service :The delivery and service By NBCLab.Com
JIANGKAI NBC-HW-80 (-20 ℃) Constant Temperature and Humidity Chamber is a test equipment used to simulate constant heat and humidity, high temperature, low temperature and alternating heat and humidity environment. It is mainly used for environmental adaptability testing of parts and materials of electronic, electrical, household appliances, automobiles and other products, and inspection of their performance indicators.
1. Adopt fully dense Compressor imported from France, environmentally friendly refrigerant R404A, equipped with fin condenser and evaporator to form an efficient and stable refrigeration system. 2. The control system adopts the original 7-inch Chinese LCD touch screen (TEMI880) imported from Korea, which has a friendly interface and supports simultaneous program control of temperature and humidity, Linear dispersion display and fault diagnosis. 3. The controller has high accuracy, temperature +/- 0.1 ℃, humidity +/- 1% RH, with 6 sets of PID control parameter setting and automatic calculation function. 4. The program capacity is large, with a maximum support of 100 sets of programs, a total of 5000 segments (SEGMENTS), each segment can be set up to 530 hours and 59 minutes. 5. With power-off program memory and automatic connection execution function after power-up, as well as program editing, locking, real-time Linear dispersion display and other control functions. 6. The inner box is made of stainless steel plate (SUS #304), and the insulation layer is rigid polyurethane foam and Glass cotton, which has a strong structure and good thermal insulation performance.
The equipment precisely controls the temperature and humidity of the air in a closed test chamber through a refrigeration system (Compressor, condenser, evaporator, expansion valve, etc.) and a heating and humidification system (heating rod, humidification tube, etc.). The control system adjusts the power output of cooling, heating and humidification through the PID algorithm according to the set program, so that the environment in the box reaches and maintains the target temperature and humidity conditions to simulate the various heating and humidity environments that the product needs to withstand.
Constant heat and humidity, high temperature, low temperature and alternating humidity cabinet test for electronic, electrical, household appliances, automobiles and other product parts and materials
GB5170.2, 3, 5, 6-95 "basic parameters of electrical and electronic products environmental test equipment method of verification low temperature, high temperature, constant heat and humidity, alternating humidity cabinet test equipment", GB 2423.1-89 (IEC68-2-1), GB 2423.2-89 (IEC68-2-2), GB/T 2423.3-93 (IEC68-2-3), GB/T 2423.4-93 (IEC68-2-30)
1. Perform parameter setting through the touch screen: select or edit the program, and enter parameters such as target temperature, humidity, and time. 2. Put the sample to be tested into the test chamber and close the box door. 3. Start the program, the equipment starts to run, and the control system automatically adjusts the environment in the box to the set conditions. 4. During the operation, the temperature and humidity Linear dispersion, program segment times, remaining time and other information can be monitored in real time through the screen. 5. After the program is completed, the device can be set to stop or enter the standby state to remove the sample.
* The equipment should be installed in a well-ventilated, non-direct sunlight, away from heat sources and flat ground. Do not use this equipment near flammable, explosive, or corrosive substances. When placing the sample, ensure that the air circulation in the box is not affected, and the total load should not exceed the specified limit. When the equipment is running, do not open the door frequently to avoid affecting the stability of temperature and humidity and the lifespan of the equipment. Regularly check refrigerant, Filter and other accessories, and perform maintenance as required. * When a fault alarm occurs, please check the fault according to the screen prompt information, or contact a professional to deal with it. * The equipment has functions such as over-temperature protection, do not modify or Shielding the safety protection device without authorization.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.