Please contact customer service
Temperature range from -20 ℃ to 150 ℃, humidity control accuracy of +/- 1% RH, using French imported Compressor and Korean imported touch screen controller, support multi-stage program editing and real-time Linear dispersion display.
Category : Temperature Humidity Chamber
Brand : JiangKai
SKU : NB042191
Service :The delivery and service By NBCLab.Com
JIANGKAI NBC-HW-225 (-20 ℃) Constant Temperature and Humidity Chamber is a test equipment used to simulate constant heat and humidity, high temperature, low temperature and alternating heat and humidity environment. It is mainly used for environmental adaptability testing of parts and materials of electronic, electrical, household appliances, automobiles and other products, and inspection of their performance indicators.
1. Adopt fully dense Compressor imported from France and environmentally friendly refrigerant R404A, equipped with fin condenser and evaporator to form an efficient and stable refrigeration system. 2. Equipped with original Korean imported TEMI880 full Chinese LCD 7-inch touch screen controller, high accuracy (temperature +/- 0.1 ℃, humidity +/- 1% RH), intuitive operation, support Linear dispersion display and multi-group PID control. 3. Large program capacity, supports up to 100 sets of programs, 5000 segments (SEGMENTS), and has the function of power-off memory and automatic connection execution after power-back. 4. The inner box is made of stainless steel plate (SUS #304), the insulation layer is rigid polyurethane foam and Glass cotton, and the box door is equipped with three-layer vacuum observation window, which has good insulation and observation performance. 5. Key electrical accessories are mostly made of internationally renowned brands, such as Danish Danfoss expansion valve, Japanese Saginomiya solenoid valve, American ALCO Filter, etc., to ensure equipment Reliability and durability.
The equipment works together with the refrigeration system (Compressor, condenser, evaporator, etc.) and the heating system (heating rod) to achieve precise control of the temperature in the box, ranging from -20 ° C to 150 ° C. Through the humidification system (humidification tube) and the dehumidification function, the humidity in the box is controlled between 20% RH and 98% RH. The controller automatically adjusts the operation of each system according to the set temperature and humidity program, simulating the required constant or alternating heat and humidity environment, so as to test the samples placed in the box.
Constant heat and humidity, high temperature, low temperature and alternating humidity cabinet test for electronic, electrical, household appliances, automobiles and other product parts and materials
GB5170.2, GB5170.3, GB5170.5, GB5170.6-95 "basic parameters of electrical and electronic products environmental test equipment method of verification low temperature, high temperature, constant heat and humidity, alternating humidity cabinet test equipment", GB 2423.1-89 (IEC68-2-1), GB 2423.2-89 (IEC68-2-2), GB/T 2423.3-93 (IEC68-2-3), GB/T 2423.4-93 (IEC68-2-30)
1. Set the required temperature and humidity program, time, and number of cycles through the touch screen controller. 2. Put the sample to be tested into the box and close the door. 3. Start the device, the controller will automatically execute the setting program, and display the temperature and humidity Linear dispersion and running status in real time. 4. During the running of the program, the sample status can be viewed through the observation window, and the controller has an alarm function to prompt abnormalities. 5. After the program is completed or manually stopped, the sample is removed and the results are evaluated.
Equipment should be operated by trained personnel and follow safety procedures. When placing the sample, ensure that the air circulation in the box is not affected, and the trend and return trend are not blocked. Regularly check and clean the equipment, especially the condenser, humidified water tray and other parts, to ensure normal operation. * After low temperature or high humidity test, care should be taken to prevent condensation or temperature difference Impact when opening the door to take lofting samples. If the equipment is not used for a long time, it should be cleaned and regularly powered on for maintenance. When a fault occurs, refer to the fault information displayed by the controller or contact a professional to deal with it. Do not disassemble key components by yourself.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.