Temperature range -40~ 150 ℃, humidity control range 20~ 98% RH, Temperature Fluctuation only 0.5 ℃. Using French imported Compressor and environmentally friendly refrigerant, equipped with Korean imported touch screen controller, support multi-group program editing and Linear dispersion display.
Category : Temperature Humidity Chamber
Brand : JiangKai
SKU : NB042196
Service :The delivery and service By NBCLab.Com
JIANGKAI NBC-HW-100 (-40 ℃) Constant Temperature and Humidity Chamber is a test equipment for simulating constant heat and humidity, high temperature, low temperature and alternating heat and humidity environment. Interior volume is 100L. The equipment is mainly used for inspection of electronic, electrical, household appliances, automobiles and other product parts and materials under specific temperature and humidity conditions. Performance indicators and adaptability.
1. Adopt full-tight Compressor imported from France, with environmentally friendly refrigerant R404A to ensure efficient and stable refrigeration system. 2. Equipped with the original TEMI880 all Chinese LCD 7-inch touch panel imported from Korea, the operation is intuitive, and it supports simultaneous program control of temperature and humidity, Linear dispersion display and fault alarm display. 3. High controller accuracy, temperature +/- 0.1 ℃, humidity +/- 1% RH, with multiple sets of PID control and automatic calculation function. 4. The program capacity is large, the maximum support is 100 sets of programs, a total of 5000 segments (SEGMENTS), and each segment can be repeability up to 9999 times. 5. Equipped with power-off program memory and automatic connection execution function after power-up to ensure the continuity of the test. 6. The inner box is made of stainless steel plate (SUS #304), and the insulation layer is rigid Polyurethane foam and Glass cotton to ensure good temperature uniformity and Stability.
The equipment precisely controls the temperature and humidity of the air in a closed test chamber through a refrigeration system (including Compressor, condenser, evaporator, expansion valve, etc.) and a heating and humidification system. The control system adjusts the output of cooling, heating and humidification components through PID calculus according to the set program, so that the environment in the box reaches and maintains the target temperature and humidity conditions to simulate the environment stress that the product needs to undergo.
Temperature and humidity adaptability test of electronic, electrical, household appliances, automobiles and other product parts and materials
GB5170.2, 3, 5, 6-95 "basic parameters of electrical and electronic products environmental test equipment method of verification low temperature, high temperature, constant heat and humidity, alternating humidity cabinet test equipment", GB 2423.1-89 (IEC68-2-1), GB 2423.2-89 (IEC68-2-2), GB/T 2423.3-93 (IEC68-2-3), GB/T 2423.4-93 (IEC68-2-30)
1. Set the required temperature and humidity program, time, and number of cycles through the touch screen. 2. Place the sample in the inner box and close the door. 3. Start the device, the system will automatically run according to the setting program, and display the temperature and humidity Linear dispersion in real time. 4. During the test, the operating status and alarm information can be monitored through the screen. 5. After the test is completed, the equipment is stopped according to the program and the sample is taken out.
Equipment should be installed in a well-ventilated, non-direct sunlight and away from heat sources. Do not use this equipment in flammable, explosive or corrosive environments. When placing the sample, ensure that the air circulation in the box is not affected, and the total load should not exceed the specified capacity. • Regularly check the refrigerant, Filter and other accessories to ensure the normal operation of the system. • When the equipment is running or just stopped, do not touch the surface of the inner box and the heating and cooling components to prevent burns or frostbite. • When there is a fault alarm, please check and eliminate the fault according to the screen prompt information before running. • When not in use for a long time, the power should be cut off and cleaned and maintained.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.