Please contact customer service
Impact conversion within 5 minutes with a temperature range of -40 ° C to + 150 ° C. Equipped with PID full digital automatic control, PWM cold control energy saving technology and pure aluminum fin evaporator, energy consumption can be effectively reduced and precise temperature control can be achieved.
Category : Thermal Shock Test Chamber
Brand : JiangKai
SKU : NB042210
Service :The delivery and service By NBCLab.Com
JIANGKAI NBC-LC-50 (-40 ℃) Thermal Shock Test Chamber is mainly used to test the tolerance of materials in extremely high temperature or extremely low temperature instantaneous alternating environment, simulating chemical changes or physical damage caused by thermal expansion and contraction of products. The equipment adopts PID automatic Control system to ensure the accuracy and Reliability of the test. It is suitable for metal, plastic, rubber, electronics and other industries to evaluate the performance of material structures or composites. The products are divided into two-box and three-box, which meet a number of national standards and industry specifications.
1. Adopt programmable color screen TEMI8226S Touchscreen controller imported from Korea, with intuitive operation and powerful data saving function. 2. It has the functions of booking the switch machine, ending the planning setting, and automatically saving the data of the power failure. Linear dispersion. 3. Real-time experimental Linear dispersion analysis, equipped with RS232, USB Data storage connection interface. 4. At the end of the test, the product to be tested will automatically return to normal temperature to avoid frost and dew condensation protection mechanism. 5. Using servo refrigerant Flow rate control technology, effective energy saving of more than 30%. 6. The experiment was carried out in a cycle, and it was effective to defrost once every 5 days, and the defrosting only took 2 hours, which did not affect the Impact time. 7. Adopt pure aluminum fin evaporator to effectively reduce energy storage time and Energy consumption. 8. With Dual-Box and Three-Box testing capabilities, meeting test specifications. 9. Adopting new PWM cold control technology can reduce energy consumption by about 40% under low temperature conditions. 10. The dual cascade Water-Cooled refrigeration system composed of imported French Taikang fully enclosed Compressor has high refrigeration efficiency.
The equipment adopts the forced ventilated equilibrate temperature control method (BTC). When the refrigeration system works continuously, the Control system controls the heater output through PID operation according to the set temperature point to achieve dynamic equilibrate. The refrigeration system adopts an inverse carro cycle, which is composed of two refrigeration cycles at high temperature and low temperature. Energy is transferred through evaporation condenser to transfer heat in the working room to achieve cooling. The air circulation device exchanges heat through the built-in fan to improve the airflow to increase Temperature Uniformity.
Electronics components, automation components, communication components, auto parts, metals, chemical materials, plastics, defense industry, aerospace, military industry, BGA, PCB substrate, electronic chip IC, semiconductor ceramic and polymer materials
GB/T 2423.1 - 2008 Test A, GB/T 2423.2 - 2008 Test B, GB-T10592-2008, GJB150.3-198, GJB360A-96 Method 107, GJB150.5-86, GB-2423.1-89 (IEC68-2-1), GB-2423.2-89 (IEC68-2-2), GJB360.8-87 (MIL-STD-202F), GBJ150.3 (MIL-STD-810D), GJB150.4 (MIL-STD-810D), GJB150.3-86, GJB150.4-86, GJB150.5-86, MIL, IEC, JIS specifications
1. Setting program: Set temperature, time and other parameters through the Touchscreen controller. 2. Place the sample: Place the sample to be tested in the sample chamber. 3. Start running: Select program running or constant running mode to start the test. 4. Monitoring process: Linear dispersion and status are monitored through the observation window and controller display. 5. End the recovery: After the test, the equipment automatically returns the sample to normal temperature to avoid frost and dew condensation. 6. Data storage: Save or export test data through RS232 or USB interface.
* Ambient Temperature should be kept at 5-40 ℃, Environmental humidity ≤ 80% R.H. * Guaranteed performance conditions are Ambient Temperature ≤ 30 ° C and no condensation. * Safety protection including over-temperature in the studio, overpressure/overload/oil pressure in the refrigerator, short circuit/overload in the heater, overload in the blower motor and leakage protection in the system. * Power requirements are AC380V, 50~ 60Hz, Power 10~ 15KW. The sample chamber is left standing, and it is necessary to ensure that the sample is placed firmly during testing. Regularly check the refrigeration system and electrical components to ensure the normal operation of the equipment.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.