Please contact customer service
Adopt PID full digital automatic control and PWM cold control technology to achieve +/- 0.2 ℃ High Accuracy and energy saving of more than 30%. With hatchback and Three-Box test functions, the temperature impact can be completed within 5 minutes, and the pure aluminum fin evaporator reduces the energy storage time.
Category : Thermal Shock Test Chamber
Brand : JiangKai
SKU : NB042212
Service :The delivery and service By NBCLab.Com
JIANGKAI NBC-LC-100 (-40 ℃) Thermal Shock Test Chamber is mainly used to test the tolerance of materials in extremely high temperature or extremely low temperature instantaneous alternating environment, simulating the condition of discontinuous conversion between high temperature and low temperature of products. The equipment can enable various items to complete the test in the shortest time to detect chemical changes or physical damage caused by thermal expansion and contraction, such as finished product cracking, broken layer, displacement, etc. The product adopts PID automatic Control system to ensure easy operation and Reliability of test results. This equipment is required by the metal, plastic, rubber, electronics and other material industries. It is divided into two-compartment and three-compartment to meet different test methods and internal structural requirements.
1. Using programmable color screen TEMI8226S Touchscreen controller imported from Korea, the display is intuitive and easy to operate. It has functions such as data saving, reservation switch, end planning setting and power failure automatic data saving Linear dispersion. 2. Equipped with RS232, USB Data storage connection interface, supports real-time experimental Linear dispersion analysis. 3. At the end of the test, the product to be tested will automatically return to normal temperature to avoid frost and dew condensation protection mechanism. 4, the use of servo refrigerant Flow rate control technology, effective energy saving of more than 30%. 5. The experiment was carried out in a cycle, and it was effective to defrost once every 5 days, and the defrosting only took 2 hours without affecting the Impact time. 6, the use of pure aluminum fin evaporator, effectively reduce energy storage time and save energy. 7. With Dual-Box and Three-Box testing capabilities, meeting test specifications. 8. Adopting new PWM cold control technology, it can reduce energy consumption by 40% under low temperature conditions. 9. The refrigeration system adopts a set of 2 × 6HP imported French Taikang fully enclosed Compressor composed of a binary cascade Water-Cooled refrigeration system. 10. The air conditioning adopts the forced ventilated equilibrating temperature control method (BTC), and the heater output is controlled by PID automatic operation to achieve dynamic equilibrating. 11. The box is made of SUS304 stainless steel liner and polyurethane foam insulation material, and the observation window is equipped with multi-layer hollow insulation Glass and lighting. 12, with perfect Safety protection measures, including studio overtemperature, refrigerator overpressure/overload/oil pressure, heater short circuit/overload, blast motor overload and system leakage protection.
The Thermal Shock Test Chamber achieves temperature impact through a high-temperature heat storage area, a low-temperature cold storage area, and a product test area. Its refrigeration system uses a binary cascade refrigeration cycle, including a high-temperature refrigeration cycle and a low-temperature refrigeration cycle. Energy is transferred through the evaporative condenser, and the heat energy in the studio is transferred through the two-stage refrigeration system to achieve cooling. The refrigeration Working Principle is based on the reverse carrot cycle. After the refrigerant is adiabatically compressed by the Compressor, it is isothermally exhaled by the condenser, and then adiabatic expansion and cooling by the expansion valve. Finally, it is isothermally absorbed by the evaporator to reduce the temperature of the object to be chilled down, and the cycle repeats to achieve the The temperature control adopts the forced ventilated equilibrating method (BTC). In the case of continuous operation of the refrigeration system, the Control system controls the output of the heater through PID automatic calculation according to the set temperature point, and finally achieves dynamic equilibrating.
Electronics components, automation components, communication components, auto parts, metals, chemical materials, plastics, defense industry, aerospace, military industry, BGA, PCB substrate, electronic chip IC, semiconductor ceramic and polymer materials
GB/T 2423.1 - 2008 Test A, GB/T 2423.2 - 2008 Test B, GB-T10592-2008, GJB150.3-198, GJB360A-96 Method 107 Temperature impact test, GJB150.5-86 Temperature impact test, GB-2423.1-89 (IEC68-2-1) Test A: Low temperature test method, GB-2423.2-89 (IEC68-2-2) Test B: High temperature test method, GJB360.8-87 (MIL-STD-202F) high temperature life test, GBJ150.3 (MIL-STD-810D) high temperature test method, GJB150.4 (MIL-STD-810D) low temperature test method, GJB150.3-86, GJB150.4-86, GJB150.5-86, MIL, IEC, JIS specifications
1. Set the required Temperature Impact Program, Temperature range and time parameters through the programmable Touchscreen controller. 2. Place the sample to be tested on the sample rack in the product testing area. 3. Select the running mode (program running or constant running) and start the device. 4. The equipment automatically performs a temperature Impact test between the high temperature heat storage area and the low temperature cold storage area according to the setting program. 5. After the test, the equipment automatically warms the product to room temperature to avoid frost and condensation. 6. View, save or export experimental data and Linear dispersion through the controller.
• Equipment Ambient Temperature should be maintained between 5 ° C and 40 ° C, Environmental humidity ≤ 80% R.H. • To ensure performance (e.g. minimum temperature -65 ° C), it is recommended that Ambient Temperature ≤ 30 ° C and no condensation. • Power supply voltage of the equipment is AC380V, 50~ 60Hz, Power 10~ 15KW, need to ensure that the power supply matches. • Before operation, please confirm that all Safety protection devices function normally, such as over temperature, overvoltage, overload, leakage and other protection. • The equipment has an independent over-temperature protection instrument and the equipment Working time cumulative Timer, please pay attention regularly. • The sample chamber is in a standing mode, please place the sample reasonably to ensure Temperature uniformity. • The left side of the equipment is equipped with a φ 50mm lead hole, and attention should be paid to the standardization of lead installation. • The refrigerant adopts the specified model, and non-professionals should not operate the refrigeration system. • Perform regular equipment maintenance, such as defrosting according to instructions (about once every 5 days).
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.