Please contact customer service
With a wide temperature impact range of -40 ° C to + 150 ° C, the temperature conversion can be completed within 5 minutes. Equipped with PID full digital automatic control and PWM cold control technology, it can effectively save energy and achieve accurate temperature control, and supports Dual-Box or Three-Box test mode.
Category : Thermal Shock Test Chamber
Brand : JiangKai
SKU : NB042213
Service :The delivery and service By NBCLab.Com
JIANGKAI NBC-LC-150 (-40 ℃) Thermal Shock Test Chamber is mainly used to test the resistance of materials to extremely high temperature or extremely low temperature. It simulates the situation that the product is not continuously in high temperature or low temperature, and can complete the test in the shortest time. The equipment is used to test the tolerance of the material structure or composite in a continuous environment of extremely high temperature and extremely low temperature in an instant, and to detect the chemical changes or physical damage caused by thermal expansion and contraction of the sample. The product is divided into two-box and three-box type, and the PID system is used for full digital automatic control, which is easy to operate.
1. Adopt programmable color screen TEMI8226S Touchscreen imported from Korea, the screen is intuitive and easy to operate, and the data storage function is super long. 2. It has functions such as booking the switch machine, ending the planning setting, and automatically saving the data during power outages. Linear dispersion. 3. Real-time experimental Linear dispersion analysis, equipped with RS232, USB Data storage connection. 4. At the end of the test, the product to be tested will automatically return to normal temperature to avoid frost and dew condensation protection mechanism. 5, the use of servo refrigerant Flow rate control technology, effective energy saving of more than 30%. 6. The experiment was carried out in a cycle, and it was effective to defrost once every 5 days, and it only took 2 hours to defrost, which did not affect the impact time. 7, the use of pure aluminum fin evaporator, effectively reduce energy storage time and energy saving. 8. With Dual-Box and Three-Box testing capabilities, meeting test specifications. 9, the use of new PWM cold control technology implementation of low temperature energy-saving operation, in low temperature conditions can reduce energy consumption by 40%. 10, the use of forced ventilated equilibrate temperature control (BTC), by improving the air flow, greatly improve Temperature Uniformity. 11. Adopt a set of 2 × 6HP imported French Taikang fully enclosed Compressor composed of a binary cascade Water-Cooled refrigeration system. 12, with perfect Safety protection measures, including studio overtemperature, refrigerator overpressure, overload, leakage and other multiple protection.
The equipment realizes temperature impact through the structural design of high temperature heat storage area, low temperature cold storage area and product test area. The forced ventilated equilibrate temperature regulation method (BTC) is adopted. In the case of continuous operation of the refrigeration system, the Control system controls the output of the heater through PID automatic calculation according to the set temperature point to achieve dynamic equilibrate. The refrigeration system adopts binary cascade Water-Cooled refrigeration, which includes two refrigeration cycles of high temperature and low temperature. Energy is transferred through evaporative condenser, and the heat energy in the studio is transferred through the two-stage refrigeration system to achieve cooling. The refrigeration cycle adopts reverse carrot cycle, which achieves the purpose of cooling through compression, condensation, expansion and evaporation.
Electronics components, automation components, communication components, auto parts, metals, chemical materials, plastics, defense industry, aerospace, military industry, BGA, PCB substrate, electronic chip IC, semiconductor ceramic and polymer materials
GB/T 2423.1 - 2008 Test A, GB/T 2423.2 - 2008 Test B, GB-T10592-2008, GJB150.3-198, GJB360A-96 Method 107 Temperature impact test, GJB150.5-86 Temperature impact test, GB-2423.1-89 (IEC68-2-1) Test A: Low temperature test method, GB-2423.2-89 (IEC68-2-2) Test B: High temperature test method, GJB360.8-87 (MIL-STD-202F) high temperature life test, GBJ150.3 (MIL-STD-810D) high temperature test method, GJB150.4 (MIL-STD-810D) low temperature test method, GJB150.3-86, GJB150.4-86, GJB150.5-86, MIL, IEC, JIS specifications
1. Set temperature, time and other parameters through the programmable color screen Touchscreen controller. 2. Select the program running or constant running mode. 3. Start the equipment, and the refrigeration and heating systems operate automatically according to the PID calculation. 4. The device completes the Temperature Impact Conversion within 5 minutes. 5. After the test, the product to be tested automatically returns to normal temperature. 6. Data storage and analysis can be performed via RS232 or USB interface.
* Ambient Temperature should be kept between 5 and 40 ℃. * Environmental humidity should be ≤ 80% R.H. * To ensure performance (such as reaching a minimum temperature of -65 ° C), Ambient Temperature is recommended to be ≤ 30 ° C and no condensation. * Equipment has multiple Safety protection, but still needs regular inspection and maintenance. Samples are left standing on a sample rack for testing. * The equipment adopts Air-Cooled heat dissipation, and it is necessary to ensure that it is well ventilated. * Power requirements are AC380V, 50~ 60Hz, Power 10~ 15KW.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.