$ 3833.00Ex works
Equipped with 7-inch touch controller to support 120 program settings, Temperature range 0~ 150 ℃ accuracy +/- 0.5 ℃, multi-wing air supply cycle to ensure uniform distribution of temperature and humidity, with fault self-diagnosis and multiple safety protection mechanisms.
Category : Temperature Humidity Chamber
Brand : Apkjgroup
SKU : NB042318
Service :The delivery and service By NBCLab.Com
APKJ AP-HX-30A programmable humidity chamber mainly provides complex high and low temperature alternating test environment and test conditions for the testing of electronic parts, industrial materials, finished product research and development, production and inspection. The device adopts 7-inch super touch AP-900 intelligent programmable temperature and humidity controller, supports 120 programs, 100 segments per program, and has USB connection, data export and import and communication functions.
1. Adopt 7-inch large touch AP-900 intelligent programmable temperature and humidity controller, support 120 sets of programs, each set of 100 segments, can set program cycle, connection and final action 2. The controller can be connected to the computer through the LAN interface to realize functions such as remote programming, data collection, and remote control switches 3. Utilize a multi-wing blower for strong air circulation to avoid dead ends and ensure uniform indoor temperature and humidity distribution 4. Complete safety protection device, automatically displaying fault status and cutting off power when abnormal, providing Troubleshooting method 5. Mainly composed of control panels, switchboards, thermal insulation compartments, blowers, heaters, humidifiers, and refrigerators, providing a variety of specifications and sizes
The equipment works together through a refrigeration system, a heating system and an air circulation system to achieve temperature and humidity control. The refrigeration system uses imported Compressors (France Taikang or Japan Hitachi) and environmentally friendly refrigerants, and heat exchange through evaporators, condensers and other components; the heating system uses nickel-chromium heaters; the air circulation system is driven by long-axis motors and wind turbines to ensure uniform distribution of temperature and humidity. The controller collects data through the Sensor and adjusts the operation of each system.
Electronics Communication, Chemical, Hardware, Rubber, Toys, Scientific Research
GB/T10589-2008、GB/T10586-2006、GB/T10592-2008、GB/T2423.1-2008、GB/T2423.2-2008、GB/T2423.3-2006、MIL-STD810D、GB/T2423.4-2008、GJB150.9-1986、GB2423.34-2012、MIL-STD883C
1. Configure an independent AC220V power supply to ensure that the voltage range is AC (220 +/- 10) V, the frequency is (50 +/- 0.5) Hz, and the protective ground wire grounding resistance is less than 4Ω. 2. Install the equipment in a site without strong vibration, flat ventilation, strong electromagnetic field and flammable and explosive substances 3. Connect the controller to the computer (optional), design the program or operate the controller directly 4. Set up the test program, including Temperature range, Humidity range, number of cycles and other parameters 5. Start the device, monitor the running status, check the fault prompt and deal with it when it is abnormal. 6. After the test is completed, export the data and turn off the power
○ It is forbidden to test or store flammable, explosive, volatile matter, corrosive substances, biological samples, and strong electromagnetic emission source samples The equipment should be free from strong vibration, strong electromagnetic field, flammable and explosive corrosive substances and dust ○ Ensure that the ground is flat and ventilated, and leave appropriate maintenance space ○ The power supply needs to be equipped with an independent air or power switch, which meets the requirements of single-phase two-wire + protective ground wire ○ The working environment temperature should be kept at 5~ 30 ℃, humidity ≤ 85%, air pressure 86kPa~ 106kPa ○ Regularly check the Compressor, heater and other components to ensure the normal operation of the protection device
We recommend a programmable temperature and humidity test chamber. It supports multi-segment program control, allowing it to simulate the complex alternating temperature and humidity environments you require. The controller is powerful, capable of setting up 120 programs with 100 segments each, facilitating your cyclic testing. The chamber employs a powerful forced air circulation system to ensure uniform temperature and humidity, delivering more reliable test results. It also complies with multiple national standards, making it suitable for research and quality inspection in industries such as electronics and electrical appliances.
The controller and data logging are indeed crucial. It is recommended to choose an intelligent controller with a large touchscreen, as it will make operation and program setup more intuitive and convenient. Pay attention to whether the number of program groups and segments it supports is sufficient for your testing plan. It's best to have a USB interface, allowing test data to be directly recorded to a USB drive for easy export and analysis later. Additionally, if you may need to centrally manage multiple devices over a network in the future, check whether communication interfaces, such as RS485, are reserved for better scalability.