$ 4168.00Ex works
7-Inch touch controller supports 120 program cycles, using multi-wing air supply to ensure uniform temperature and humidity, equipped with French Taikang Compressor and American DuPont environmental protection refrigerant, Temperature range -20 ℃~ + 150 ℃, Humidity range 20~ 98% R.H.
Category : Temperature Humidity Chamber
Brand : Apkjgroup
SKU : NB042323
Service :The delivery and service By NBCLab.Com
The programmable humidity chamber AP-HX-50B is an environmental test equipment produced by APKJ, which mainly provides complex high and low temperature alternating test environment and test conditions for the testing of electronic parts, industrial materials, finished product research and development, production, inspection and other links. It adopts 7-inch super touch AP-900 intelligent programmable temperature and humidity controller, supports 120 programs, 100 segments per program, and has USB connection, RS232 communication and other functions.
1. Adopt 7-inch large touch AP-900 intelligent programmable temperature and humidity controller, support 120 sets of programs, each set of 100 segments, can set program cycle, connection and final action 2. The controller can be connected to the computer through the LAN interface to realize remote programming, data collection, and remote switching 3. The multi-wing blower has strong air circulation to avoid dead ends and ensure uniform distribution of indoor temperature and humidity 4. Complete safety protection device, automatically displaying fault status and cutting off power when abnormal, providing Troubleshooting method 5. Mainly composed of control panels, switchboards, insulation compartments, blowers, heaters, humidifiers, and refrigerators, providing a variety of standard sizes and specifications
The equipment works together through the refrigeration system (including the original imported French Taikang or Japanese Hitachi fully enclosed Compressor, evaporator, condenser, etc.), the heating system (nickel-chromium heater) and the air circulation system (circulating air duct, long-axis motor) to achieve temperature and humidity control. The controller adjusts the operation of each component according to the preset program, and uses the multi-wing blower to force air circulation to ensure uniform and stable temperature and humidity in the test chamber.
Electronics Communication, Chemical, Hardware, Rubber, Toys, Scientific Research
GB/T10589-2008、GB/T10586-2006、GB/T10592-2008、GB/T2423.1-2008、GB/TT2423.2-2008、GB/T2423.3-2006、MIL-STD810D、GB/T2423.4-2008、GJB150.9-1986、GB2423.34-2012、MIL-STD883C
1. Ensure that the installation site is free from strong vibration, strong electromagnetic field, flammable and explosive corrosive substances, and the ground is flat and ventilated 2. Configure an independent AC220V power supply to meet the requirements of single-phase two-wire + protected ground wire, voltage (220 +/- 10) V, frequency (50 +/- 0.5) Hz, and ground resistance less than 4Ω 3. Set temperature and humidity parameters and cycle conditions through a controller or computer design program 4. Start the equipment, monitor the running status and record data 5. After the test is completed, process it according to the end of the program and turn off the power supply.
Prohibit the testing or storage of flammable, explosive, volatile matter, corrosive substances, biological samples, strong electromagnetic emission source samples • There should be no strong vibration or strong electromagnetic field around the equipment, and there should be appropriate maintenance space • The power supply needs to be independently configured to meet the voltage, frequency and grounding requirements, and does not include external environment items such as ventilated pipes and power cables • The working environment temperature should be 5~ 30 ℃, humidity ≤ 85%, air pressure 86kPa~ 106kPa • Regularly check the safety protection device to ensure that the power can be automatically cut off in case of abnormality
Recommend a programmable temperature and humidity test chamber. It meets the wide temperature range of -20°C to 150°C and the humidity range of 20% to 98% RH that you mentioned. The temperature uniformity of this device can reach ±2.0°C, with humidity deviation within ±2% RH, demonstrating excellent precision. It is recommended primarily because it utilizes an imported high-efficiency compressor and an advanced controller, enabling precise simulation of complex environmental conditions. This makes it suitable for reliability testing of products sensitive to temperature and humidity, such as electronic components.
Applicable. The programmable constant temperature and humidity test chamber is a commonly used equipment in material research and development as well as quality inspection. It can accurately set and execute complex temperature and humidity variation programs, such as high temperature and high humidity, low temperature and low humidity, and rapid cyclic changes, making it ideal for evaluating the stability, aging resistance, or changes in physical properties of new chemical materials under different environmental stresses. The equipment complies with multiple national and international testing standards, ensuring the accuracy and comparability of your experimental data.
This feature is actually quite practical. Having multiple program groups and segments means you can set up more complex and longer automated testing processes. For example, you can pre-program multiple test stages that the product needs to undergo—such as high-temperature storage, low-temperature startup, and humidity-thermal cycling—into a continuous running program. The equipment can then automatically complete these tests without requiring manual intervention for switching. This significantly improves testing efficiency, making it particularly suitable for scenarios such as the R&D stage, where repeated validation under different working conditions is needed, or production line environments where products require long-term, multi-condition comprehensive assessments.